Installing and Connecting the MDF 
and Telephones

03-300686

Issue 3

Release 5.0

January 2008

Содержание 03-300686

Страница 1: ...Installing and Connecting the MDF and Telephones 03 300686 Issue 3 Release 5 0 January 2008 ...

Страница 2: ... additions or deletions to this documentation to the extent made by the Customer or End User Link disclaimer Avaya Inc is not responsible for the contents or reliability of any linked Web sites referenced elsewhere within this documentation and Avaya does not necessarily endorse the products services or information described or offered within them We cannot guarantee that these links will work all...

Страница 3: ... blocks on the wall 21 Mounting 110P type terminal blocks on a frame 24 Installing Cable Slack Managers 25 Chapter 3 Installing the patch panel 29 Installing patch panels 29 Cross connecting the media gateway to the patch panels 29 Chapter 4 Media gateway connections to the MDF 33 Equipment room cabling labels 33 Cable routing guidelines 36 Trunk cables among network interface sneak fuse panel and...

Страница 4: ...ecting trunk pairs using concentrator cables 65 Connecting trunk pairs to media gateway using jumper wires to establish 3 pair modularity 67 Chapter 6 Installing and wiring telephones and trunks 69 Wiring telephones and trunks 69 Connecting telephones 70 Connectable telephones and consoles 70 Connecting a typical telephone 73 Connecting adjunct power 74 Connecting an analog station or 2 wire digit...

Страница 5: ... Panel 99 Installing telephones used only for emergency transfer trunk auxiliary field 104 Installing telephones used for emergency transfer and as normal extension trunk auxiliary field 105 Installing external ringing 106 Installing the queue warning indicator 107 Chapter 7 Installing and wiring telephone power supplies 109 1145B2 power supply 109 Important warning for 1145B2 power supply 110 Mou...

Страница 6: ...ter 8 Testing the complete configuration 135 Testing port network equipment 136 Checking port network status for each media gateway 136 Checking circuit pack configuration 137 Testing the TN2312BP Internet Protocol Server Interface circuit pack 138 Testing Expansion Interface circuit packs if used 139 Testing time division multiplexing bus for each port network 140 Testing expansion interface exch...

Страница 7: ...Contents Issue 3 January 2008 7 LED indicators 147 Telephone console LEDs 148 Attendant console LEDs 148 Terminal alarm notification 148 DS1 Converter circuit pack LEDs 148 SPAN LEDs 150 Index 151 ...

Страница 8: ...Contents 8 Installing and Connecting the MDF and Telephones ...

Страница 9: ...omplete configuration on page 135 Audience This documentation is for the following audiences Trained field installation Technical support personnel Authorized Business Partners How to use this documentation Use this documentation as a guide to install and connect MDFs and telephones For information about a particular task use the index or table of contents to locate the page number where the infor...

Страница 10: ...y effort to ensure that the information in this book is complete and accurate However information can change after we publish this documentation Therefore the Avaya Support Web site might also contain new product information and updates to the information in this book You can also download these updates from the Avaya Support Web site To view any book you must have a copy of Adobe Acrobat Reader N...

Страница 11: ...m the Avaya Support Web site http support avaya com Installing the Avaya G650 Media Gateway 03 300685 Provides procedures for installing and cabling a G650 Media Gateway connecting to the customer s network and testing the complete configuration Adding New Hardware for Avaya Servers and Gateways 03 300684 Provides information on installing adjunct and peripheral equipment that an S8400 S8500 or S8...

Страница 12: ...cedures for Avaya Communication Manager 5 0 Media Gateways and Servers 03 300432 Provides information on how to troubleshoot and replace various components The following job aids are also available on the CD ROM Documentation for Avaya Communication Manager Media Gateways and Servers Approved Grounds Provides a description of all approved grounds Connector and Cable Diagrams Pinout Charts Provides...

Страница 13: ...the following pieces of equipment Sneak fuse panels and emergency transfer units on page 13 110 type hardware on page 13 Cable Slack Manager on page 14 Sneak fuse panels and emergency transfer units You need about 8 inches 20 centimeters of horizontal wall space for each column of sneak fuse panels Horizontal wall space must also be provided for emergency transfer units 110 type hardware The trunk...

Страница 14: ... 14 Site satellite and adapter locations on page 14 Sizing 4 pair station cables on page 15 Sizing 25 pair and multiple 25 pair station cables on page 15 3 pair station cable circuits on page 15 4 pair station cable circuits on page 15 Information outlet locations The customer or marketing representative must provide floor plans showing the information outlet locations and types flush or surface m...

Страница 15: ...ks Use the following information to determine the cable size cable pairs required for either 3 pair or 4 pair circuits Note the length and size on the floor plan to aid in the ordering and installation of the station cables 3 pair station cable circuits To determine the size of station cables containing 3 pair circuits multiply the number of 3 pair circuits required at the satellite location by 3 ...

Страница 16: ... and attendant console power This field is used for emergency transfer wiring paging equipment music sources and so forth The distribution field contains four cross connect areas The purple field port field terminates 25 pair cables from the media gateway Each line circuit pack connects to one 25 pair row of the 110 type terminal block One 25 pair cable is required for each line circuit pack Note ...

Страница 17: ...e 25 pair cables The cables are provided in 10 foot 3 meter and 15 foot 4 5 meter lengths Figure 1 Example MDF connections MCC1 Media Gateway shows the cross connections for common circuit packs See this figure when cross connecting wire pairs to the MDF Figure 1 Example MDF connections MCC1 Media Gateway Figure 2 Example MDF connections G650 Media Gateway on page 18 shows a detailed example of th...

Страница 18: ...Distribution Field White Field 5 Trunk Auxiliary Field 6 Purple Field 7 Yellow Field 8 Green Field 9 Satellite Closet 10 Auxiliary Cabinet Yellow Field 11 White Field 12 Blue Field 13 Cross Connect Jumpers 14 103A or Modular Wall Jack 15 4 Pair Line Cord 16 To Line Circuit Pack 17 To Trunk Circuit Pack 18 To Network Interface 48 VDC 48 VDC RETURN cadlmdfb LAO 091103 01 02 03 04 05 06 07 08 09 10 1...

Страница 19: ...RIN G 10 3 4 5 6 8 9 Powe r 2 7 11 12 13 Powe r 1 14 FA N OR PO WE R FA IL FA N AN D PO WE R OK AC INP UT DC INP UT AC TIV E RIN G FA N OR PO WE R FA IL FA N AN D PO WE R OK AC INP UT DC INP UT AC TIV E RIN G 10 3 4 5 6 8 9 Powe r 2 7 11 12 13 Powe r 1 14 FA N OR PO WE R FA IL FA N AN D PO WE R OK AC INP UT DC INP UT AC TIV E RIN G FA N OR PO WE R FA IL FA N AN D PO WE R OK AC INP UT DC INP UT AC ...

Страница 20: ...White From MDF to satellite locations 3 pair Each label identifies two rows on the terminal block The upper half identifies the row above it and the lower half identifies the row below it The labels are inserted into the clear plastic designation strips furnished with the terminal blocks The strip is snapped in place between the terminal block rows Label code number 1220A comcode 103970000 contain...

Страница 21: ...gure 6 110P type terminal blocks 900 pair on page 23 3 To mount the first trunk auxiliary field terminal block partially install 2 3 4 inch 12 wood screws 7 11 1 inch 19 5 centimeter apart on the left side of the horizontal line on the wall 4 Slide the bottom terminal block ft onto the mounting screws and mark the upper mounting screw locations 5 Remove the terminal block and partially install the...

Страница 22: ...ight of the screw just installed Repeat Steps 4 5 and 6 12 If installing a vertical patch cord trough in the distribution field repeat Step 6 13 Repeat Steps 11 and 12 until all the terminal blocks and vertical patch cord troughs in the distribution field are installed Figure 5 110A type terminal blocks 300 pair Figure notes 1 4 feet 1 22 meters 2 6 6 feet 2 meters 3 7 68 inches 19 5 centimeters 4...

Страница 23: ...terminal blocks 900 pair Figure notes 1 4 feet 1 22 meters 2 Horizontal Line 3 7 68 inches 19 5 centimeters 4 47 5 inches 120 6 centimeters 5 5 31 inches 13 5 centimeters 6 7 8 inch 2 22 centimeters 7 23 inches 58 4 centimeters 8 8 feet 2 43 meters 9 AC Power Strip 10 Floor Line r758421b MMR 031496 ...

Страница 24: ...e 24 Each 1110A2 provides the space to mount five terminal blocks patch cord troughs on each side of the frame A cable support structure apparatus mounting 1110C1 mounts directly on top of the 1110A2 and provides support for all cables routed to and from the frame See Table 1 Apparatus mounting frame ordering information on page 25 Figure 7 1110A2 and 1110C1 apparatus mountings Figure notes 1 1110...

Страница 25: ...r 3 Repeat Step 2 until all cable slack managers are installed Note Note Nine 1 4 inch 0 63 centimeter holes are provided in a cable slack manager base if earthquake mounting is required If a base is mounted on an uneven floor shims may be required for leveling and to assure proper fit of the covers Holes are provided in the sides of the base for bolting cable slack manager together Obtain bolts a...

Страница 26: ...r MDF cables in place Figure 8 Cable routing through Cable Slack Manager example for MCC1 Media Gateway on page 26 and Figure 9 Cable routing through Cable Slack Manager example for SCC1 Media Gateway on page 27 show cable clamp placement and cable routing Figure 8 Cable routing through Cable Slack Manager example for MCC1 Media Gateway Figure notes 1 Top of Media Gateway 2 Cable Slack Manager 3 C...

Страница 27: ...Slack Manager example for SCC1 Media Gateway Figure notes 1 Top of Media Gateways 2 Cable Clamps 3 Cable Ties Optional 4 Power Cord 5 Cable Slack Manager 6 Cable Slack Manager Cover Removed 7 Main Distribution Frame MDF 8 Route Cables Along Path Shown 9 Port Cables 3 5 1 2 r758155 CJL 031496 4 ...

Страница 28: ...Installing the main distribution frame 28 Installing and Connecting the MDF and Telephones ...

Страница 29: ...ure 10 Typical RMC patch panel installation on page 30 while you perform this procedure To install patch panels 1 Use the supplied mounting screws to mount the patch panels on the rack below media gateway A or above the topmost media gateway 2 Attach B25A cables to the patch panels and the circuit pack amphenol connectors Note Note Connect 24 port DCP or analog circuit packs to the 24 port patch p...

Страница 30: ... and Telephones Figure 10 Typical RMC patch panel installation Figure notes 1 Circuit pack amphenol connectors and B25A cables 2 IP server interface adapter and green CAT5 cable 3 24 port patch panels 4 8 port patch panel 5 To network cadlpat LJK 022502 1 2 3 3 4 5 ...

Страница 31: ...98 4 1 10 19 4 13 22 2 11 20 5 14 23 3 12 21 6 15 24 9 18 7 16 25 8 17 Port Tie Trunk Port MET Line 4 4 Port Tie Trunk w E M Signaling Port Data Line 8 Port Digital 8 Port BRI 12 Port Hybrid 8 Port DID 8 Port Analog Port CO 8 8 1 10 19 4 13 22 2 11 20 5 14 23 3 12 21 6 15 24 9 18 7 16 25 8 17 Port Digital 24 16 DS1 Port Analog Port Analog 16 24 Port Digital ...

Страница 32: ...Installing the patch panel 32 Installing and Connecting the MDF and Telephones ...

Страница 33: ...rs on page 25 This section has information about Equipment room cabling labels on page 33 Cable routing guidelines on page 36 Trunk cables among network interface sneak fuse panel and media gateway on page 38 And procedures for Installing cables between media gateway and MDF on page 38 Installing connector cables between auxiliary cabinet and MDF on page 39 Equipment room cabling labels The purple...

Страница 34: ... to the trunk auxiliary field The bottom blue yellow label is for 25 pair cables connecting to site satellite closets See Table 2 Equipment room labels Figure notes 1 Purple Label Port Cable 2 Blue Yellow Label Building and Floor 3 Yellow Label Auxiliary 4 Blue Yellow Label Site or Satellite Table 2 Equipment room labels Label name Range Port Cable 1A1 1A20 1B1 1B20 1C1 1C20 1D1 1D20 1E1 1E20 Buil...

Страница 35: ... stick label on 25 pair cable connector shows the proper way to install a label on a 25 pair cable connector Install the label near the rear of the connector so it is not obscured by the media gateway connector retainers It can also be installed on the skin of the cable near the connector Figure 13 Self stick label on 25 pair cable connector Table 3 Cable connector building label ordering informat...

Страница 36: ...edia gateway to the top and bottom of the MDF respectively Figure 14 Cable routing to top terminal blocks Figure notes 1 Main Distribution Frame 2 AC Power Cord AC powered media gateways only 3 Cable Slack Manager Number 1 4 Trunk Auxiliary Field 5 Station Distribution Field 6 Cable Slack Manager Number 2 7 Cable Slack Manager Number 3 8 Media Gateway s 9 To Building Cables 10 10 AWG 25 6 square m...

Страница 37: ...media gateway to the wall Place the cable beside one of the rows of columns in the cable slack manager Note Note Retainers mounted on the columns keep the cable from protruding above the top of the base of the cable slack manager Determine the length of the cable required to reach from the cable slack manager to the assigned connecting terminal block Use D rings on the wall to support the cable Th...

Страница 38: ...ct the media gateway to the 110 type terminal blocks in the purple field The 1 pair patch cords jumper wires are then run from the purple terminal block rows to the green terminal block rows in order to establish the correct 3 pair modularity Installing cables between media gateway and MDF To install cables between the media gateway and the MDF 1 Install D rings on the wall between the cable slack...

Страница 39: ... distribution frame 1 Install D rings on the wall between the cable slack manager and the terminal connecting blocks mounted on the MDF 2 Install a self sticking port label on the rear of each connector on the B25A connector cable See Figure 16 Self stick label on 25 pair cable connector on page 39 3 Labels should be positioned so the cabinet connector retainers do not obscure them 4 At the rear o...

Страница 40: ...Media gateway connections to the MDF 40 Installing and Connecting the MDF and Telephones ...

Страница 41: ...ect the MDF to satellite closets Then station cables are used to branch out to site closet locations that are located physically close to information outlets Information outlets may be wired directly to the MDF a satellite closet or site closet The following hardware and cabling is used Information outlets on page 41 modular jacks Station cables on page 42 Closets on page 43 Station circuit distri...

Страница 42: ...nded types Single modular plug ended 4 pair station cable Use this cable between adapters and information outlets that require push on connections It can also be used when 4 pair station cables are field terminated on the 110 type terminal blocks in the equipment room or satellite closet and modularly connected to information outlets The station cables are available in the following lengths 10 fee...

Страница 43: ...points for multiple site closets However information outlets may be wired directly to a satellite closet Site closets are the last cross connection point before the end user information outlet Satellite and site closets may be used to apply bulk station power to information outlets Satellite locations Satellite locations are closets that provide an administration point using cross connect equipmen...

Страница 44: ...ing for the administration of remote powering Adapters are used at site locations to terminate the 25 pair station cables and provide connection points modular jacks for power adapters and 4 pair station cables The 258A and BR2580A adapters plug into a 25 pair female cable connector These adapters divide the 25 pair cable into six 4 pair modular jack circuits See Figure 23 258A and BR2580A Adapter...

Страница 45: ...ts The 4 pair station cables can be run directly from the equipment room to the information outlets if 4 pair terminal blocks are used in the distribution field See Figure 19 4 pair run to equipment room or satellite location on page 47 The station cables must be field terminated on the 110 type terminal blocks If 110 type terminal blocks are used with a modular plug ended station cable an adapter...

Страница 46: ...ution Frame MDF 2 3 Pair Connecting Blocks 3 4 Pair Connecting Blocks 4 Purple Field 5 Blue Field 6 Patch Cord or Cross Connect Jumpers 7 To Media Gateway 3 Pair Modularity 8 B25A Cable 9 Connectorized Staggered Finger Multiple 25 Pair Cable 10 258A or BR2580A Adapter 11 Information Outlet 12 4 Pair Circuit 13 DIW Station Cable D Inside Wire 2 3 8 8 4 9 7 6 1 1 2 1 2 1 1 1 0 1 3 r7 6 4 7 9 7 a C J...

Страница 47: ... 4 Pair Circuit 3 Blue Field 4 DIW Station Cable D Inside Wire 5 Information Outlet Figure notes 1 Part of MDF 2 3 Pair Connecting Blocks 3 4 Pair Connecting Blocks 4 Purple Field 5 Patch Cord or Cross Connect Jumpers 6 Blue Field 7 To Media Gateway 3 pair modularity 8 A25D Cable 9 258A or BR2580A Adapter 10 Information Outlet 11 4 Pair Circuit DIW station cable D Inside Wire 3 4 1 5 2 2 r764798a ...

Страница 48: ...White Field 5 Patch Cord or Cross Connect Jumpers 6 To Media Gateway 3 Pair Modularity 7 A25D Cable 3 Pair Circuits 8 B25A Cable 9 Connectorized staggered finger Multiple 25 Pair Cable 10 4 Pair Connecting Blocks 11 Blue Field 12 258A or BR2580A Adapter 13 Information Outlet 14 4 Pair Circuit DIW Station Cable D Inside Wire 15 Part of Satellite Location 16 4 Pair Circuits B25A Cable 2 2 3 8 8 4 4 ...

Страница 49: ...1 Part of Main Distribution Frame MDF 2 3 Pair Connecting Blocks 3 Purple Field 4 Blue Field 5 Patch Cord or Cross Connect Jumpers 6 To Media Gateway 3 Pair Modularity 7 B25A Cable 8 3 Pair Circuits 9 356A Adapter 10 Information Outlet 11 3 Pair Circuit in 4 Pair Wire 12 DIW Station Cable D Inside Wire 8 7 1 9 10 11 12 r758533a CJL 031196 2 2 4 3 6 5 ...

Страница 50: ...on adapters are used to provide modular connectivity either directly to a telephone or to an information outlet See Figure 23 258A and BR2580A Adapters and Figure 24 356A Adapter on page 51 Figure 23 258A and BR2580A Adapters Figure notes 1 BR2580A Adapter 2 258A Adapter 3 25 Pair Male Ribbon Connector 4 4 Pair Modular Jacks 8 Pins 3 4 4 1 2 crdfadp CJL 101596 ...

Страница 51: ...cks 6 pins each connected to 25 pair ribbon connector Table 4 Adapter ordering information Description Comcode 258A Adapter 102605136 BR2580A Adapter 403384720 356A Adapter 104158829 400B Adapter 103848859 400B2 Adapter 104152558 ZD8AJ Adapter 103881421 451 Adapter Gray 103942272 451 Adapt White 103786240 crdf356 CJL 101296 1 2 ...

Страница 52: ...ing representative See Figure 25 Port Assignment Record Form on page 53 for an example of the form These forms contain the port assignments and identify the extension numbers terminal number of the telephones Enter the jack assignments at the equipment room The Port Assignment Record should have the following information Station or trunk type or feature service Building location floor room desk ou...

Страница 53: ...Completing a provisioning plan Issue 3 January 2008 53 Figure 25 Port Assignment Record Form ...

Страница 54: ...e media gateway from over voltages Analog trunks use the 507B sneak protector or equivalent Over voltage protection is normally provided by the local telephone company DS1 E1 T1 circuits require isolation from exposed facilities This isolation may be provided by a CSU T1 LIU E1 or other equipment that provides equivalent protection Analog telephones use 146 Series Line Protectors combined over vol...

Страница 55: ...rrent protection Figure notes 1 507B sneak current protector 2 25 pair male connector in 3 25 pair female connector out 4 220029 fuses inside panel Use a small screwdriver to pry top cover off Table 5 Sneak fuse panel ordering information Description Comcode 157B Connecting Block 403613003 SCP 110 Protector 406948976 507B Sneak Current Fuse Panel 107435091 220029 Sneak Current Fuse 407216316 25 pa...

Страница 56: ... and installed on the 157B connecting block Fifty protectors are required per block Install the 507B near the network interface or patch panels with locally obtained 12 x 3 4 inch screws or equivalent Table 6 Sneak fuse connector pinout on page 56 is a pinout of the cable wiring and associated fuse numbers Table 6 Sneak fuse connector pinout Connector pin numbers Pair fuse number 26 1 1 27 2 2 28 ...

Страница 57: ...ace or the main distribution frame MDF 2 Hold the panel against the mounting surface and mark the mounting screw locations Drill pilot holes at the marked locations and partially install a locally obtained 12 x 3 4 inch screw into the two bottom mounting slots 3 Slide the sneak fuse panel onto the mounting screws and tighten the screws securely 4 Install a locally obtained 12 x 3 4 inch screw into...

Страница 58: ...n distribution frame MDF The CBC can be a 10 AWG 25 6 mm2 wire tie wrapped to the exposed telecom cables a metal cable shield around the exposed cables or six spare pairs form the exposed cable A minimum of 12 spacing should be maintained between the CBC and other power ground or non exposed communications cables Installing coupled bonding conductor wires To install coupled bonding conductor wires...

Страница 59: ...em Single point Ground Discharge Bar 5 DC Power Cabinet J58890R or new DC system 6 Ground Wire for Battery 7 Battery Frame Ground 8 DC Battery Cabinet 9 Main AC Supply AC Mains 10 AC to DC power cabinet 11 To Next DC powered Media Gateway 12 DC load circuit breakers 50A 50A 50A 50A 48 VDC 48 V 48 V 48 V 48 V RTN 48 V RTN 48 V RTN MCC MCC MCC 10 AWG RED 10 AWG 6 AWG AC phase AC phase 10 AWG 10 AWG ...

Страница 60: ...er Ground Discharge Bar to the MDF CBC block See Figure 28 Coupled Bonding Conductor on page 61 2 Connect one end of the 10 AWG 25 2 5 mm2 wire to the single point ground block or Ground Discharge Bar 3 Route the wire next to the 25 pair cables connecting to the trunk auxiliary purple field 4 Tie wrap the 10 AWG 25 2 5 mm2 wire to the 25 pair cables 5 Connect the 10 AWG 25 2 5 mm2 wire to the MDF ...

Страница 61: ... Wraps 4 Cable Shield or Six Spare Pairs 5 Ground on Carbon Block Protector or Equivalent 6 Trunk Cable to Network Interface 7 10 AWG 25 2 5 mm2 Wire 8 To Network Media Gateways 9 Battery Plant Ground Discharge Bar for Single Point Ground 10 Cross Connect Ground Block 11 Main Distribution Frame MDF 12 To Other Cross Connect Ground Blocks 13 Approved Ground 14 Coupled Bonding Conductor CBC cbc_gnd_...

Страница 62: ... to 24 connects to an identically labeled terminal block row at the satellite closet See Figure 29 Example 3 pair labeling to information outlet on page 63 This is always the case for either 1 point or 2 point administration The satellite symbol must be installed at all connection points between the blue field and the information outlet It must also be installed at the information outlet itself Fi...

Страница 63: ...tellite Location 3 Work Location 4 White Row on 110 Terminal Block 5 Purple Row on 110 Terminal Block 6 Blue Row on 110 Terminal Block 7 Central Location for Terminals 1 through 6 8 D Inside Wire Cut Down to Connecting Block 9 258A Adapter 10 Information Outlet 11 Telephone 12 To Port Connector on Media Gateway Media Gateway 1 Position B Slot 03 crdf5pr CJL 103096 ...

Страница 64: ...tor label on the assigned 110 type terminal block row 2 On the expansion control carrier cable place a yellow auxiliary label on the connectors at each end of the cable 3 Write AUX on each label Figure notes 1 Equipment Room 2 To Central Location for Terminals 1 through 6 3 Blue Row on 110 Terminal Block 4 Purple Row on 110 Terminal Block 5 To Port Connector on Media Gateway Media Gateway 1 Positi...

Страница 65: ...5A cables between the network interface and sneak fuse panels 2 Connect A25D cables from the sneak fuse panels to the 110 type terminal block connectors in the green field 3 Connect patch cords jumper wires from the terminal block in the green field to the associated terminal block in the purple field 4 Connect the single fingered end of the concentrator cables to the 110 type terminal block conne...

Страница 66: ...ntrator cables Figure notes 1 Trunk Auxiliary Field 2 To Expansion Control Carrier AUX Connector MCC1 Media Gateway only 3 Concentrator Cable WP90929 List 1 4 Concentrator Cable WP90929 List 3 5 A25D Male to Male Cable 6 Alternate Block Rows 7 RJ21X RJ2GX Network Interface 8 Sneak Fuse Panel 9 B25A Cable 10 Central Office Trunks 11 Media Gateway NEW796 THC 031296 ...

Страница 67: ...modularity for trunk pairs for 1 pair trunks on page 67 2 Connect A25D B25A cables from the sneak fuse panels to the 110 type terminal block type connecting block connectors in the green field 3 Connect 1 pair patch cords jumper wires from each 110 type terminal block row in the green field to the 110 type terminal block rows in the purple field for 1 pair central office CO trunks or in Figure 33 ...

Страница 68: ...ng the MDF and Telephones Figure 33 3 pair modularity for trunk pairs for 3 pair Tie trunks Figure notes 1 Green Field 2 1 Pair Jumpers 3 Pairs 4 Purple Field 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 18 19 20 21 22 23 24 3 r758537b MMR 031496 ...

Страница 69: ...ing a phone that is on an IP trunk too close to a fax machine can cause problems If the phone is too close the handset can pick up the tones from the fax machine and change itself into the fax mode To prevent this turn down the volume on the fax machine or move the phone set further away from the fax machine or on the IP Codec Set screen change ip codec set set the Fax field to off if not sending ...

Страница 70: ...Connector and Cable Diagrams Pinout Charts 555 245 773 for information on pinouts Connecting telephones This section includes the various analog digital and IP telephones can be connected to the media gateway including Connectable telephones and consoles on page 70 Connecting a typical telephone on page 73 Connecting adjunct power on page 74 Connecting an analog station or 2 wire digital station o...

Страница 71: ...tocol IP DECT 46xx series 4601 4602 4602SW 4606 4610SW 4612 4620 4620SW 4621SW 4622SW 4624 4625SW 4630 4630SW 4690 Internet Protocol IP 62xx series 6211 6219 Analog 64xx series 6402 D 6408D 6416D D M 6424D D M Digital 9040 Avaya TransTalk Wireless 96xx series Avaya one X Deskphone Edition IP telephones Internet Protocol IP Avaya Agent Deskphone 16CC Enhanced Attendant Consoles 302D Digital 603F Av...

Страница 72: ...Connecting the MDF and Telephones 606A Avaya CallMaster VI ACD Console Digital Softphones Netmeeting H 323 IP Softphone CentreVu IP Agent Softconsole Internet Protocol IP Table 7 Connectable telephone and consoles continued Telephone and console models Type 3 of 3 ...

Страница 73: ...backup as the media gateway The maximum cabling distance for the console powered from the media gateway is 350 feet 100 meters The general steps to connect a telephone are 1 Choose a device to connect such as a 302D Attendant Console 2 Choose the port circuit pack and its slot number such as cabinet 1 slot 02 3 Choose a port circuit on the port circuit pack such as Port 05 4 Install cross connect ...

Страница 74: ...ery backup as the media gateway See Auxiliary connector outputs MCC1 and SCC1 Media Gateways only on page 81 Note Note Adjunct power can be provided locally at the telephone or console by either the 1151B1 or 1151B2 power supply Adjunct power can be provided from the equipment room or equipment closet with the 1145B power unit See Installing and wiring telephone power supplies on page 109 for powe...

Страница 75: ... Choose the media module to use and its media gateway and slot number For example MM711 Analog Media Module Media Gateway 002 Slot V2 3 Choose a port circuit on the MM711 Media Module for example port 03 4 Install cross connect jumpers to connect the pins from the 2 wire digital station to the appropriate pins on the MM711 Media Module Table 8 Station pinout chart on page 76 shows a printout chart...

Страница 76: ...cuit pack 2 See the job aid titled Option Switch Settings 555 245 774 for detailed information 3 Install cross connect jumpers to connect the pins from the tie trunk circuit pack to the appropriate leads on the external tie trunk Figure notes 1 2500 Type Analog Station 2 MM711 Analog Media Module Position 1V301 Table 8 Station pinout chart Jack Name 1 2 3 4 5 6 7 8 BRI T TX RX RX TX V GND ADJUNCT ...

Страница 77: ...om one media gateway to another one or any other Avaya configuration Figure 38 Digital Tie Trunk wiring on page 78 shows the connections 1 Install cross connect jumpers to connect the pins from the digital trunk circuit pack to appropriate pins on the manufacturer s or supplier s external digital trunk 2 Set option switches on the port circuit pack digital trunk 3 See the job aid titled Option Swi...

Страница 78: ... on page 79 For cable descriptions see DS1 cables on page 80 Pinout of C6F cable on page 80 Collocated DS1 interface trunks Two TN464HP DS1 Interface circuit packs can be in collocated configurations A DS1 Interface circuit pack in one configuration can be connected to a DS1 in another configuration A C6D cable can be used if the distance is less than 50 feet 15 2 meters If the distance is between...

Страница 79: ...te Note A 3150 CSU is shown a 120A Integrated CSU ICSU may be used Contact your Avaya representative for maximum cabling distances for the 3127 series CSU or the 120A ICSU Figure 39 Typical connections to channel service unit Figure notes 1 Connector to DS1 Interface Circuit Pack 2 C6C Cable For Distances Over 50 ft 15 m Use C6E Cable s 3 T1 Channel Service Unit CSU 3150 Shown 4 T Tip 5 R Ring 6 T...

Страница 80: ...located cabinets C6E connector cable 100 feet 31 meters shielded cable equipped with a 50 pin male connector on one end and a 50 pin female connector on the other end Use this cable as an extension cable between the DS1 tie trunk circuit pack and other connector cables C6F connector cable 50 feet 15 meters shielded cable equipped with a 50 pin male connector on one end and a 3 inch 8 centimeter st...

Страница 81: ...ency transfer units Three 48 VDC power sources for remotely powering three attendant consoles or telephone adjuncts A relay contact that actuates a customer supplied light bell or similar device The relay can activate when a major minor or warning condition occurs The device connected to the alarm leads must not exceed a rating of 30Vac RMS or 60Vdc max at 0 75A max The customer provided alarm cir...

Страница 82: ... Transfer Relay Power BK O O BK 37 12 48 GND BK G G BK 38 13 48 GND BK BR BR BK 39 14 48 GND BK S S BK 40 15 48 GND Y BL BL Y 41 16 48 GND Y O O Y 42 17 48 GND Y G G Y 43 18 Not Connected Y BR BR Y 44 19 GND 48 AUX Power Y S S Y 45 20 GND 48 V BL BL V 46 21 GND 48 V O O V 47 22 Not Connected V G G V 48 23 Ext Alarm A3 Ext Alarm Return Table 11 Auxiliary lead appearances at AUX connector continued ...

Страница 83: ... W White BL Blue O Orange G Green BR Brown S Slate Grey R Red BK Black Y Yellow V Violet External alarm with signal incoming to server 3External alarm with signal outgoing from server Table 12 Station pinout chart Jack Name 1 2 3 4 5 6 7 8 BRI T TX RX RX TX V GND ADJUNCT Vadj T0 V GNDVoice RRVoice V S0 TTVoice DSS QUEST DTX DRX OKdig V V DSS ISDN BRI A GND TX RX V BRI U TX RX V GND DCP TIP RING AN...

Страница 84: ...the port circuit pack to the modular jacks as shown in Figure 40 3 pair and 4 pair modularity on page 84 Then plug the terminal into the modular jack Adjunct power connection locations on page 85 shows three methods of connecting adjunct power Figure 40 3 pair and 4 pair modularity Figure notes 1 Port Circuit Pack 2 Media Gateway Connector Pins 3 Pair Modularity 3 Main Distribution Frame MDF Pins ...

Страница 85: ...nstall a bulk power supply at the satellite location 3 If only one telephone needs adjunct power install the individual power supply at the work location Figure 41 Example adjunct power connections Figure notes 1 Typical Display Telephone 2 Individual Power Supply Such as 1151B1 or 1151B2 3 Information Outlet Modular Jack 4 4 Pair D Inside Wire DIW Cable 5 Satellite Site or Adapter Location 6 25 P...

Страница 86: ...al functions of an attendant console and its optional 26A1 or 24A1 selector console derive their power from an auxiliary power source Of the maximum of 27 attendant consoles 3 of the consoles can derive auxiliary power from the media gateway and through the auxiliary cable located in the trunk auxiliary field Provide auxiliary power for a primary attendant console through this cable so the console...

Страница 87: ...ralleling these endpoints can cause electrical damage to the consoles or cause the circuit pack to remove power from the consoles Dual wiring of 2 wire and 4 wire endpoints Do not simultaneously wire a 2 wire and 4 wire endpoint to the same equipment location in an MDF The Avaya configurations use separate circuit packs to interface 2 and 4 wire endpoints Installing the attendant console To instal...

Страница 88: ...ypical major alarm input is from an uninterruptible power supply UPS The media gateway provides a relay contact that can operate a customer provided alarm such as a light or bell The circuitry and power source are customer provided The device connected to the alarm leads must not exceed a rating of 30Vac RMS or 60Vdc max at 0 75A max The customer provided alarm circuit must also meet the requireme...

Страница 89: ...al alarms The adjunct equipment must provide an isolated contact closure across the alarm leads provided by the Avaya media gateway The contact must be rated at a minimum of 60 VDC with a current carrying capacity of 5 mA minimum 2 Connect an external alarm output Green White and White Green 3 Note which device connects to which alarm and give this information to your Avaya representative for trou...

Страница 90: ...stall an A25D male to male cable between the RJ21X network interface and a sneak fuse panel 2 At the main distribution frame MDF connect jumper wires between one row connecting block in the green field and up to three rows connecting blocks in the purple field to concentrate the analog line pairs Table 14 Alarm Inputs at TN2312BP Adapter DB9 Alarm Connector Color AUX Connector Pair Name For additi...

Страница 91: ...ng analog telephones on page 92 shows the connections for 1 to 8 off premises analog telephones Figure 45 Connections to 24 out of building telephones on page 93 shows the connections for up to 24 off premises analog telephones Concentrations of analog line pairs are used at both buildings to minimize the off premises wiring required At the MDF jumpers must be connected between one row connecting ...

Страница 92: ...25 Pair Connector 4 Multi Pair Protector Units Primary Protectors with Heat Coils or Equivalent with Sneak Current Protection 5 356A Adapter 6 B25A Cable Male to Female 7 Out Of Building Analog Telephones 8 Part of Main Distribution Frame MDF 9 Station Side 10 Media Gateway Side 11 White Field 12 Purple Field 13 Cross Connect Jumpers 14 Tip and Ring Wires 15 To Analog Line Circuit Pack 8 7 1 9 10 ...

Страница 93: ... current protector Figure notes 1 Locally Engineered Cables and Equipment 2 25 Pair Connector 3 Multi Pair Protector Units Primary Protectors with Heat Coils or Equivalent with Sneak Current Protection 4 B25A Cable Male to Female 5 Concentrator Cable WP90929 List 1 6 356A Adapter 7 Out of Building Wiring 8 Out Of Building Analog Telephones 9 Part of Main Distribution Frame MDF 10 Station Side 11 M...

Страница 94: ...n an exposed environment Digital Out of Building Telephone Protection Digital out of building telephones require protection at both building entrances The 4C3S 75 Enhanced Protector and the ITW Linx Enhanced Protector can be used to protect digital telephones and digital line circuit packs These units provide primary and sneak current protection The 4C3S 75 is equipped with a heat coil for sneak c...

Страница 95: ... types of primary protection It must be installed as the only protection on the line entering the building For the 4C3S 75 protector there are a variety of 25 50 and 100 pair protector panels equipped with 110 type connecting blocks and or RJ21X connectors Installing the data link protector The maximum range for out of building digital telephones is 3400 feet when using 24 AWG 5 0 5 square millime...

Страница 96: ...ATS trunks can provide emergency transfer capability The 808A Emergency Transfer Panel provides emergency trunk bypass or power fail transfer for up to five incoming CO trunk loops to five selected station sets The 808A equipment s Ringer Equivalency Number REN is 1 0A At the MDF the unit is controlled by a connection to a yellow terminal row connecting block in the trunk auxiliary field The unit ...

Страница 97: ...anel The 808A connects to the MDF with B25A or A25B cable The panel can be installed on any mounting frame in either a vertical or horizontal position The housing has ears for screw mounting and cutouts for snap mounting the unit in an 89 type mounting bracket See Figure 48 808A Emergency Transfer Panel mounting on page 99 Task List Typical Emergency Transfer Panel and Telephone Installation Insta...

Страница 98: ...ircuit Start Selection Switches 3 Trunk Identification Label 4 25 Pair Male Connector 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 12 EMERGENCY TRANSFER PANEL CIRCUIT 1 2 POWER TRUNK TEST SWITCHES TRUNK OPTION LOOP START GROUND START BOTH SWITCHES MUST BE THROWN TO ACTIVATE TRUNK OPTION TRANSFER TEST SWITCH ACTIVATED NORMAL OPERATION TRUNK IDENTIFICATION TRUNK LINE EXT LOC 808A led808a LJK 040896 ...

Страница 99: ...uit start selection switches see Figure 47 808A Emergency Transfer Panel on page 98 These are the first 10 two position switches on the left side of the Emergency Transfer Panel They are used to set each of the five incoming trunk lines to either loop start or ground start Two switches are used for each circuit switches 1 and 2 are used for circuit 1 switches 3 and 4 are used for circuit 2 and so ...

Страница 100: ...B9 alarm cable to the TN2312BP adapter in the A carrier only See Figure 42 IPSI 2 cabling on page 88 and Figure 43 Sample Issue 1 IPSI 2 alarm cable connectivity on page 89 6 On the trunk identification label at the bottom of the panel record the trunk line extension and location for each circuit 7 To each telephone designated as an emergency terminal attach a label identifying it as such The labe...

Страница 101: ... pair connector 26 W BL TTC1 Tip PBX Trunk Circuit 1 1 BL W RTC1 Ring PBX Trunk Circuit 1 27 W O TTK1 Tip CO Trunk Circuit 1 2 O W RTK1 Ring CO Trunk Circuit 1 28 W G TLC1 Tip PBX Line Port 1 3 G W RLC1 Ring PBX Line Port 1 29 W BR TST1 Tip Emergency Terminal 1 4 BR W RST1 Ring Emergency Terminal 1 30 W S TTC2 Tip PBX Trunk Circuit 2 5 S W RTC2 Ring PBX Trunk Circuit 2 31 R BL TTK2 Tip CO Trunk Ci...

Страница 102: ...l 3 38 BK G TTC4 Tip PBX Trunk Circuit 4 13 G BK RTC4 Ring PBX Trunk Circuit 4 39 BK BR TTK4 Tip CO Trunk Circuit 4 14 BR BK RTK4 Ring CO Trunk Circuit 4 40 BK S TLC4 Tip PBX Line Port 4 15 S BK RLC4 Ring PBX Line Port 4 41 Y BL TST4 Tip Emergency Terminal 4 16 BL Y RST4 Ring Emergency Terminal 4 42 Y O TTC5 Tip PBX Trunk Circuit 5 17 O Y RTC5 Ring PBX Trunk Circuit 5 43 Y G TTK5 Tip CO Trunk Circ...

Страница 103: ...from Aux Cable 25 S V 48PX 48V from AUX Cable Figure notes 1 To Network Interface Circuitry 2 To TN747B or Equivalent Central Office Trunk Circuit Pack 3 To Blue or White Station Distribution Field 4 To Power Transfer Unit 5 DB9 Alarm Cable to TN2312BP Adapter Table 18 Pin assignments for 25 pair connector continued 3 of 3 TC TK LC ST XR 1m AL 1M 3M ALARM MONITORS 3m 3w TC TK LC ST TC TK LC ST TC ...

Страница 104: ...ge 103 2 Connect CO trunk leads from the purple field to TC terminals on the yellow emergency transfer row connecting block for each trunk 3 Connect CO trunk leads from the green field to TK terminals on the yellow emergency transfer row connecting block for each trunk Figure notes 1 To Network Interface Facility 2 To Blue or White Station Distribution Field 3 To TN2183 or Equivalent Analog Line C...

Страница 105: ...tween the 48V and GRD terminals on the yellow emergency transfer row connecting block to the EM TRANS RELAY PWR terminal See Figure 50 Connections for telephone used for emergency transfer and as normal extension on page 104 2 Connect CO trunk leads from the purple field to TC terminals on the yellow emergency transfer row connecting block for each trunk 3 Connect CO trunk leads from the green fie...

Страница 106: ...ine circuit pack port To install external ringing 1 Wire the ringing device to the information outlet as shown in Figure 51 3 pair and 4 pair modularity on page 106 and Figure 41 Example adjunct power connections on page 85 2 Administer per the Administrator Guide for Avaya Communication Manager 03 300509 Figure 51 3 pair and 4 pair modularity Figure notes 1 Port Circuit Pack 2 Media Gateway Conne...

Страница 107: ...49 can be used in a uniform call distribution direct departmental calling UCD DDC queue The lamp is connected to an information outlet The media gateway side of the MDF is connected to an analog line circuit pack located in a port carrier Wire the queue warning indicator to the information outlet as shown in Figure 51 3 pair and 4 pair modularity on page 106 and Figure 41 Example adjunct power con...

Страница 108: ...Installing and wiring telephones and trunks 108 Installing and Connecting the MDF and Telephones ...

Страница 109: ...ribution Units on page 123 C360 converged stackable switches on page 128 Local power supplies include 1151B1 and 1151B2 Power Supplies on page 131 1145B2 power supply The 1145B2 closet power arrangement provides an uninterruptible 48 VDC power source with battery and 1146B2 distribution unit for ISDN DCP terminal equipment adjuncts and other customer supplied equipment During AC power interruption...

Страница 110: ...ctions when mounting product Openings on top and bottom of power unit are provided for ventilation Do not block or cover these openings Do not exceed recommended environmental temperatures Operate these products only from the type of power source indicated on the product labels The power unit is equipped with a 3 wire grounding plug a plug having a third grounding pin This plug will only fit into ...

Страница 111: ...ing the 1145B2 1146B2 power supply Figure 52 1145B2 1146B2 mounting arrangement on page 112 shows how the standard power supply and wall mounting plates fit together Figure 53 Expanded power distribution unit on page 113 shows the expanded power supply components power distribution unit and T cable A manual switch on the distribution unit allows the user to redirect reserve power to outputs 1 thro...

Страница 112: ...49B Shown 3 1146B2 Power Distribution Unit 4 1145B2 Power Unit 5 Power Cable 6 Nonswitched Outlet 120 VAC 20 amp or 230 VAC 15 amp 7 Battery Backup Switch Setting 1145 Power Unit 1149 Battery On Battery Reserve Charging Battery Output Power On 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 48V 48V RTN RTN Unit No Connected To 1 8 1 32 0003_1 PDH 062596 ...

Страница 113: ...istribution Unit 4 T Cable H600 347 G7 5 First 1146B2 Power Distribution Unit 6 1145B2 Power Unit 7 Nonswitched Outlet 120 VAC 20 amp or 230 VAC 15 amp 8 Battery Backup Switch Setting cadfexpw KLC 091403 2 1145 Power Unit 5 7 1146 Power Distribution Unit 1146 Power Distribution Unit 1149 Battery 1 On Battery Reserve Charging Battery Output Power On 4 3 6 1 32 1 8 8 8 ...

Страница 114: ...rews 3 The 1145B2 Power Supply is snap fit onto the bottom wall mounting plate without tools 4 An installer provided insulated ground wire 16 AWG 12 1 2 square millimeters or greater is required to connect the power supply frame ground lug to an approved ground The frame ground screw is located next to the AC outlet to the left of the unit Mounting the 1146B2 Power Distribution Unit See the 1146B2...

Страница 115: ...crews securely 3 Plug the battery cord into the power supply s right rear receptacle The rear receptacle is indicated on the right label Installing the expanded power distribution unit A second power distribution unit can be installed to provide power to additional devices CAUTION CAUTION Total power cannot exceed 275 watts The maximum ISDN terminal mixture is 24 7500 series and 24 8500 series ter...

Страница 116: ...cribed on the label on the side of the unit 6 Remove the output power cable between the 1145B2 and the 1146B2 units The cable will not be reused 7 Connect the P1 connector end of the T cable to the bottom power distribution unit Connect the P2 connector to the top distribution unit Connect the P3 connector to the 1145B2 8 Power up the 1145B2 as described on the label on the side of the unit Poweri...

Страница 117: ... LEDs should be lit together See Table 20 Power supply LEDs on page 116 FAIL If either green or red LED is not lit after disconnecting AC power check the connections If the connections are good replace the power unit or batteries 6 Reconnect AC power to the power supply Wiring the 1146B2 Power Distribution Unit Wire endpoints to the 1146B2 while power from the 1145B2 is on A red LED lights if its ...

Страница 118: ...he terminal equipment is faulty and must be replaced If the LED is still lit find and repair the short circuit in the building wiring 3 Reconnect the terminal equipment to the wall jack and retest terminal equipment operation Figure notes 1 Power Supply Kit 2 2 5 5 0 or 8 0 Amp Hour Battery 3 1146B2 Distribution Unit 4 1145B2 Power Supply 5 Circuits 1 16 6 Circuits 17 32 7 Port Circuit 8 Main Dist...

Страница 119: ...pful tips Retain these tips for later use When using this switch the following safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons Read and understand all instructions Follow all warnings and instructions marked on this switch This product can be hazardous if immersed in water To avoid the possibility of electrical shock do not use it near w...

Страница 120: ...ernet connection Generation 1 Avaya IP telephones can receive power from the 1152A1 via an in line adapter This adapter provides the resistive signature so that the 1152A1 allows power to flow to the telephone The generation 2 telephones do not need an adapter The 1152A1 PDU has 24 10 100 Base T ports each can supply up to 16 8 watts using the internal power supply and operates on a 100 240 VAC 60...

Страница 121: ... or CAT6e straight through Ethernet cable not supplied including all eight wires 4 pairs as shown in Figure 55 Connecting telephones and other end devices to the 1152A1 PDU on page 121 Figure 55 Connecting telephones and other end devices to the 1152A1 PDU For Data In ports connect the Ethernet cable leading from the Ethernet Switch Hub to the Data port For Data Power Out ports connect the Etherne...

Страница 122: ...nal splitter separates the power and data prior to connection to the end device see Figure 56 Connecting an IP telephone with an external splitter on page 122 Figure 56 Connecting an IP telephone with an external splitter Before connecting telephones or other end devices to the 1152A1 PDU determine if It is Power over LAN Enabled or not If not you may safely connect the telephone however the port ...

Страница 123: ...ion over an Ethernet network The 1152B PDUs eliminate the need to connect each Ethernet Data Terminal such as an IP Telephone set to an AC power outlet in addition to the data port The system also removes the need for power cables local AC wall adapters and the use of a dedicated UPS for each IP telephone Some models support SNMP remote management via a separate physical RJ45 input port These unit...

Страница 124: ... electrostatic discharge Do not touch the circuit boards unless instructed to do so This product should be operated only from the type of AC and optional DC power source indicated on the label If you are not sure of the type of AC power being provided contact a qualified service person Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by perso...

Страница 125: ... Base T ports each of which can supply a minimum of 15 4 watts using the internal power supply and operates on a 100 240 volts AC 60 50 hertz power source The 1152B PDU is 1U high and fits in most standard 19 inch racks It can also be mounted on a shelf Refer to the user s guide that comes with the unit for complete installation instructions Connecting the 1152B PDU cables All of the ports on the ...

Страница 126: ...om the LAN These end devices termed Power over LAN Enabled receive power once they are connected to the 1152B PDU To safeguard devices that are not enabled the 1152B PDU detects devices that are not enabled so does not send power Note that data continues to flow using the Ethernet cable regardless of the status of the end device End devices that are not enabled to receive power directly may receiv...

Страница 127: ...onnector and polarity Power requirements are consistent with the 1152B PDU voltage and power ratings Refer to Appendix B in the user s guide that comes with the unit for voltage and power ratings To connect telephones and other end devices to the 1152B PDU 1 Connect an Ethernet cable to the telephone using an external splitter or directly if the device is Power over LAN Enabled 2 Connect the oppos...

Страница 128: ... reduce the risk of fire electric shock and injury to persons Read and understand all instructions Follow all warnings and instructions marked on this switch This product can be hazardous if immersed in water To avoid the possibility of electrical shock do not use it near water The Avaya C360 switches and modules contain components sensitive to electrostatic discharge Do not touch the circuit boar...

Страница 129: ...instructions Using the C360 switch The C360 Stackable Switch can be used to power 46xx series IP telephones in addition to providing a 10 100 megabits per second Ethernet connection The switch can form part of a stack with the G700 Media Gateway or members of the P330 stackable switching system A C360 stack can contain up to 10 switches and up to three backup power supply units The stacked switche...

Страница 130: ...vide more than 200 watts for the power over Ethernet ports Note Note Please see the Avaya C360 Manager User Guide and the Quick Start for Hardware Installation Avaya C360 Converged Stackable Switches 03 300148 for more information To connect the BUPS DC terminal unit 1 Remove the protective plastic cover over the BUPS DC inputs by unscrewing the two Phillips screws WARNING WARNING The conductors t...

Страница 131: ...tion IP telephone switch or hub 3 Check that the appropriate link LNK LEDs light up 1151B1 and 1151B2 Power Supplies The 1151B1 and 1151B2 power supplies are a local power supply The telephones or consoles connect directly to them through an RJ45 connector The 1151B2 has a battery backup These power supplies comply with the Underwriters Laboratories Inc UL Standard UL 60950 third edition For safet...

Страница 132: ...ord Do not locate this product where the cord will be abused by persons walking on it Do not overload wall outlets and extension cords as this can result in the risk of line or electric shock Disconnect the cords on this product and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is damaged or frayed If liquid has been spilled into t...

Страница 133: ...ole slots are provided on the bottom of the chassis CAUTION CAUTION Do not locate the unit within 6 inches 15 centimeters of the floor Connecting the 1151B1 or 1151B2 Power Supplies The 1151B1 is a standard no battery backup power supply unit The 1151B2 is a battery backup version of the 1151B1 Either power supply can support one telephone with or without an adjunct The maximum loop range is 250 f...

Страница 134: ...Installing and wiring telephone power supplies 134 Installing and Connecting the MDF and Telephones ...

Страница 135: ...port The term cabinet refers to five G650 Media Gateways TDM cabled together in a rack making up one port network A port network is defined as a group of media gateways connected together with one TDM bus Perform these tasks to test the configuration CAUTION CAUTION To prevent unnecessary trouble tickets do not enable the alarms Alarm Origination feature until all installation and administration p...

Страница 136: ...Checking port network status for each media gateway The port network status may suggest problem areas Tests described later provide more specific diagnostic information To check the port network status for each media gateway 1 Type status port network number 1 64 and press Enter 2 Verify the screen displays a Port Network Status screen similar to Figure 60 Sample port network status screen for Cab...

Страница 137: ...t power supply circuit packs Do not attempt to correct any problems until after the diagnostic tests that you run later in the configuration tests 3 Note any boards with a VINTAGE column entry of NO BOARD or CONFLICT A u indicates unassigned ports and a number indicates the port has been translated status port network 1 PORT NETWORK STATUS Major Minor Warning Carrier PN Control FIBER PN Alarms Ala...

Страница 138: ... IPSI 01A test results screen Page 1 Avaya S8700 Multi Connect on page 139 list configuration all Page 4 SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u unassigned t tti p psa 01B01 IP SERVER INTFC TN2312BP HW33 FW045 01 02 03 04 05 06 07 08 01B02 EXPANSION INTRFC TN570C 000002 01B03 DS1 INTERFACE TN464HP 000020 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20...

Страница 139: ...igure 63 Sample test results for Expansion Interface Board 2A01 on page 140 This example is for board 2a01 3 If any result is FAIL check the connections for the fiber optic link 4 Repeat Steps 1 and 2 for each Expansion Interface circuit pack test ipserver interface 1a Page 1 TEST RESULTS Port Maintenance Name Alt Name Test No Result Error Code 01A TONE BD 46 PASS 01A TONE BD 52 PASS 01A0201 ETR P...

Страница 140: ...ult is FAIL for any test check the connectors of the TDM bus cables in PN 2 4 Repeat these steps for each PN to check the TDM bus cables Figure 64 Sample test results for TDM bus port network 1 TEST RESULTS Port Maintenance Name Alt Name Test No Result Error Code 02A01 EXP INTF 237 PASS 02A01 EXP INTF 238 PASS 02A01 EXP INTF 240 PASS 02A01 EXP INTF 241 PASS 02A01 EXP INTF 244 PASS 02A01 EXP INTF 3...

Страница 141: ...press Enter A screen similar to Figure 66 Sample of port network status after expansion link is set on page 142 displays 5 Verify that the MODEs of the expansion links have changed 6 If any problems are indicated check the TDM cables and the inter cabinet cables ICC in the associated port network Figure 65 Sample of port network status before expansion link is set status port network PORT NETWORK ...

Страница 142: ...l perform properly after installation and administration If problems occur or more extensive tests are required see the maintenance book for your configuration Perform these tasks to complete acceptance tests Making test calls on page 143 Testing 302C attendant console on page 143 Testing selector console on page 144 status port network PORT NETWORK STATUS Major Minor Warning Carrier PN Control FI...

Страница 143: ...C attendant console To check that all lamps are operational and call another telephone in the configuration 1 Simultaneously press and hold Ringer Volume up and POS BUSY This puts the console in the self test mode Note Note Releasing the buttons returns the console to normal mode 2 Verify all lamps on display light and remain lighted Each row of lamps on the console lights and goes dark in sequenc...

Страница 144: ...ting external ringing Make a test call to the attendant console to verify ringing device sounds when the Night lamp on console is lighted If ringing device has not been installed by customer connect spare telephone to information outlet reserved for ringing device and make test call Testing queue warning indicator Make a test call to an extension associated with a uniform call distribution UCD or ...

Страница 145: ...dial tone If satisfied hang up 2 If using an analog phone dial the integrated announcement extension number to hear the announcement When the announcement is over you hear a dial tone If satisfied hang up Delete announcement To delete an announcement 1 Dial the access code followed by the integrated announcement extension number 2 When you hear a dial tone press 3 to delete the announcement and en...

Страница 146: ...TEST Extension type in 3 extension numbers in the 3 fields provided Test Type 100 _______Test Type 102 _______Test Type 105 _______ Test type Test features Test type 100 5 5 seconds of 1004 Hz tone at 0 dB Quiet until disconnect disconnect is forced after 1 minute Test Type 102 9 seconds of 1004 Hz tone at 0 dB 1 second of silence Cycle is repeated until disconnect which is forced after 24 hours T...

Страница 147: ...D descriptions If a maintenance object begins to fail some periodic tests the server will generate an alarm The server identifies three levels of alarms Major Alarms Failures that cause critical degradation of service and require immediate attention Minor Alarms Failures that cause some degradation of service but do not cause a critical portion of the configuration to be inoperable This condition ...

Страница 148: ...n telephones with administered feature buttons or the attendant console A maximum of 10 digital and or hybrid telephones may be used When an alarm occurs the green status LED associated with the assigned button is in a steady state The LED may be turned off by pressing the button associated with the LED If the LED is off and the alarm has not been resolved by the time maintenance reschedules testi...

Страница 149: ...AN LEDs Table 23 DS1 Converter yellow LED flashing states LED on LED off Condition 0 1 second 0 1 second Fiber out of frame or fiber loss of signal 0 5 second 0 5 second In frame fiber channel down The fiber channel communicating between the DS1 Converter and the other fiber endpoint EI or SNI is down 1 second 1 second In frame control channel down The control channel between the two DS1 Converter...

Страница 150: ...onds Facility is operational and alarm free AND is carrying the control channel facility A or B only Solid on red Facility is alarmed Solid off Facility is not administered or has been busied out solid on DS1 Converter active This is the normal state for an active DS1 Converter solid off DS1 Converter standby This is the normal state for a standby DS1 Converter in critical reliability configuratio...

Страница 151: ...ir station circuits 44 808A emergency transfer panel 96 99 808A emergency transfer panel examples 97 A adapter 258A 356A BR2580A ZD8AJ 43 451A extender 42 adjunct power 73 connecting 74 connection locations 85 administering patch cords and jumpers 62 alarms 147 connections 88 terminal alarm notification 148 wiring 75 analog line circuit protectors 93 analog station wiring 75 analog telephones 91 a...

Страница 152: ...fields MDF 16 D data link protector installing 95 DC power 58 DID trunk wiring 75 digital line circuit protectors 94 digital tie trunk wiring 77 direct department calling testing queue warning indicator 144 downloading this book and updates from the Web 10 DS1 converter circuit pack LEDs 148 DS1 tie trunks wiring 78 dual wiring of 2 wire and 4 wire endpoints 87 E emergency transfer panel installin...

Страница 153: ...cting media gateway 29 cross connect fields 16 emergency transfer connections 99 emergency transfer unit 96 hardware 17 installation 17 labels 20 location 19 off premises connections 90 91 media gateway cross connecting to MDF 29 media gateway installation coupled bonding conductors 58 modularity 3 pair and 4 pair 84 mounting terminal blocks 21 24 music on hold testing 145 N night ringing testing ...

Страница 154: ...tion examples 97 telephone pin designations 76 83 telephones connecting 73 emergency transfer 104 105 terminal alarm notification alarms 148 terminal blocks frame mounting 24 wall mounting 21 terminals connecting 44 terminating trunk transmission test types 146 terminating trunk transmission testing 146 test types terminating trunk transmission 146 testing 1145B2 power supply 116 complete configur...

Страница 155: ...e digital station 75 alarm 75 analog station 75 analog tie trunk 76 battery 115 CO trunk 75 DID trunk 75 digital tie trunk 77 DS1 tie trunks 78 off premises stations 90 procedures 69 telephone connection 73 wiring telephone power supplies procedures 109 Z ZD8AJ adapter 43 ...

Страница 156: ...156 Installing and Connecting the MDF and Telephones Index ...

Отзывы: