39
ATTO Technology Inc. FastStream Installation and Operation Manual
5.1.8 SCSI configuration commands
The SCSI ports are configured with default settings but may be customized to your specifications using
the CLI commands in this section.
SCSIDomainValidation
Runs Domain Validation tests on the SCSI system which
may detect problems with SCSI cables, termination or
damaged transceivers. Tape drives attached to the
FastStream should be loaded with media. The media is
not overwritten. Disable VirtualDriveResponse before
running this test and reboot the FastStream NDMP 4600
after running the test.
SCSIDomainValidation
SCSIInitID
Specifies the SCSI initiator ID to be used on the specified
SCSI port. All maps coinciding with the user-specified
SCSIInitID must be set to offline and becomes invalid
upon issuing this command. Choices are 0 to 15.
Default: 7
set SCSIInitID [sb [0-15] ]
Requires a SaveConfiguration command
get SCSIInitID
SCSIPortBusSpeed
Controls the transfer rate at which the FastStream
NDMP 4600 tries to negotiate with its SCSI devices.
Default: Ultra3
set SCSIPortBusSpeed [sb [fast | ultra | ultra2 | ultra3]
Requires a SaveConfiguration command
get SCSIPortBusSpeed [port number]
SCSIPortList
Returns a list of available SCSI ports and their current
status. Valid status values are
O.K.
and
Failed.
SCSIPortList
SCSIPortReset
Resets the specified SCSI bus.
SCSIPortReset [sb]
SCSIPortResetOnStartup
Specifies whether the SCSI port should be reset on power-
up or not.
Default: enabled
set SCSIPortResetOnStartup [sb [enabled | disabled] ]
Requires a SaveConfiguration command
get SCSIPortResetOnStartup [sb]
SCSIPortSelTimeout
Indicates the time, in milliseconds, that the FastStream
NDMP 4600 waits for a response from a SCSI device on
the selected port after a selection request.
get SCSIPortSelTimeout [sb]
SCSIPortSyncTransfer
Specifies whether synchronous SCSI transfers should be
negotiated with devices on the specified SCSI port.
Default: enabled
set SCSIPortSyncTransfer [sb [enabled | disabled] ]
Requires a SaveConfiguration command
get SCSIPortSyncTransfer [sb ]
SCSIPortTermination
Configures/reports the SCSI internal termination of the
SCSI port identified.
Default: enabled
set SCSIPortTermination [sb [ enabled | disabled]]
Requires a SaveConfiguration command
get SCSIPortTermination [sb]
SCSIPortWideTransfer
Specifies whether wide SCSI transfers should be
negotiated.
Default: enabled
set SCSIPortWideTransfer [sb [enabled | disabled] ]
Requires a SaveConfiguration command
get SCSIPortWideTransfer [sb]
SCSITargetLUNs
Controls the maximum number of SCSI LUNs per target
the unit queries during a SCSI bus scan.
Default: 8
set SCSITargetLUNs [sb] [8 | 32]
get SCSITargetLUNs [sb]