33
ATTO Technology Inc. FastStream Installation and Operation Manual
5.1.4 Maintenance commands
The CLI commands outlined in this chapter may be used to get information or perform functions which
are used in a variety of situations with the ATTO FastStream NDMP 4600.
Date
Sets the date for the FastStream NDMP 4600 if SNTP has
been disabled or is not available.
set Date [MM] / [DD] / [YYYY]
Requires a SaveConfiguration command
get Date
FirmwareRestart
Causes the FastStream NDMP 4600 to reboot, then re-
initialize its firmware.
FirmwareRestart
MaxOpTemp
Establishes/reports the maximum enclosure temperature
alarm in degrees Celsius. If the temperature of the
FastStream NDMP 4600 rises above the maximum
MaxOpTemp, thermal control event handling occurs.
Valid entries are between 55 and 70 degrees C
Default: 70
set MaxOpTemp [55-70]
Requires a SaveConfiguration command
get MaxOpTemp
MinOpTemp
Establishes/reports the minimum enclosure temperature
alarm in degrees Celsius. If the temperature of the
FastStream NDMP 4600 falls below the minimum
MinOpTemp, thermal control event handling occurs.
Valid entries are between 0 and 15 degrees
Default: 0
set MinOpTemp [0-15]
Requires a SaveConfiguration command
get MinOpTemp
OpTempWarn
Controls the number of degrees in Celsius before a
thermal control event handling occurs. Warnings are
made via system log entries. Valid entries are between 0
and 15 degrees
Default: 5
set OpTempWarn [0-15]
Requires a SaveConfiguration command
get OpTempWarn
Password
RestoreConfiguration default sets the password to the
default value
Passwords are case sensitive, 1-32 characters with no
spaces
When the password is all 0s, TCP/IP and ftp do not
validate the password and MD5 authentication are
disabled.
Default: Password
set Password
Requires a SaveConfiguration command
Reserve
Reservation of the FastStream NDMP 4600 is implicit:
once the configuration image is changed by any user of
services, the FastStream NDMP 4600 becomes
RESERVED. Executing a SaveConfiguration or\ Restore
configuration RELEASES the FastStream NDMP 4600 so
that other services users may access it. When FastStream
NDMP 4600 services interface is RESERVED, set
commands from other users are unavailable.
At least one interface must always have access to the
FastStream NDMP 4600.
Reserve
RestoreConfiguration
Restores configuration to either the default configuration
or the configuration last saved into non-volatile memory.
The saved option undoes any changes made since the last
save.
RestoreConfiguration [Default | Saved]
Содержание FastStream NDMP 4600
Страница 2: ......
Страница 3: ......
Страница 15: ...8 Configuration NDMP...
Страница 21: ...14 Firmware update...
Страница 33: ...26 Interfaces CLI...
Страница 43: ...36 Interfaces CLI...
Страница 58: ...ix ATTO Technology Inc FastStream Installation and Operation Manual...