9
ATTO Technology Inc. FastStream Installation and Operation Manual
2.2 Remote system monitoring
You may set up the FastStream NDMP 4600 to send notifications when certain events occur.
Use the
Remote Management
page of the
ExpressNAV interface to send information about the
operation of the FastStream NDMP 4600. CLI
commands may be used to set up remote monitoring.
Refer to
You may designate the person receiving notification of
conditions and the level of severity which prompt
notification. For example a recipient with a critical
severity level only receives critical messages and not
warning messages.
The severity level can be
all, warning
,
critical
or
none
.
•
All
means warnings, critical events and
informational messages are sent.
•
Critical
means only critical event notifications
are sent.
•
Warning
means only warnings and critical event
notifications are sent.
•
None
means no notification is sent.
E-mail notification
E-mail notification using SMTP (Simple Mail
Transfer Protocol) allows the FastStream NDMP 4600
to send an E-mail message to you, a network
administrator or other users when certain events occur:
• critical and warning temperature conditions
• critical and warning voltage conditions
• power
is
on
When an event occurs that warrants E-mail
notification, the FastStream NDMP 4600 scans each
of its ports until the E-mail is sent successfully. Each
attempt takes one minute. The E-mail function only
sends messages; it cannot respond to a rejection by a
server for an invalid address.
Each E-mail is time stamped when it leaves as part of
the SMTP header information.
1
If you are not already in the ExpressNAV GUI,
type the IP address of your FastStream NDMP
4600, as found in
page 5, in a standard browser and press
Enter
.
2
Click on the
Remote Management
page menu
item.
3
Click on the
enable
button in the
Notification
line.
4
Enter the SMTP Server IP address provided by
your IT administrator which is the
from
address
included in the E-mail.
If authentication is required by the SMTP Server,
a.
Go to the
Advanced CL
I page.
b.
Type
set emailusername [username]
c.
Click
Submit
or press
Enter
d.
Type
set emailpassword [password]
e.
Click
Submit
or press
Enter
f.
When the FastStream NDMP 4600 has
restarted, return to ExpressNAV
Remote Management
page (refer to
steps 1 and 2 of this procedure).
5
Enter the
Recipient
E-mail address(es).
6
From the drop-down box next to each recipient
E-mail address, select the level of severity for
which you want each address to be notified.
7
Press
Submit.
After rebooting, the FastStream NDMP 4600
sends E-mail notifications as you set them up.
Exhibit 2.2-1 shows the format of the E-mail