17
ATTO Technology Inc. FastStream Installation and Operation Manual
4.1 ATTO ExpressNAV pages
The ATTO ExpressNAV interface provides information and/or configuration parameters based on a
specific topic.
Each page of the ExpressNAV interface can be
reached through the menu at the side of each page
An image on each page’s header shows each port
in the product faceplate. Each port is clickable and
also takes you to the appropriate page.
Note
Clicking on
Submit
saves the current
configuration without a restart. A message
displays if the reconfiguration requires a
restart.
Status
Displays FastStream NDMP 4600 information:
• Vendor ID, product ID, firmware revision number
and serial number
• Valid temperature range, current temperature
and current voltage
• Ethernet port IP addresses and status
• SCSI
port
status
Serial Port
Configures the baud rate and echo parameters.
Refer to
Serial port configuration commands
Time & Date
Configures the real-time clock or accesses a
remote time server. Configurable options are:
• Enable/disable Simple Network Time Protocol
• Time Server and time zone
• Manually set time and manually set date
Refer to
Ethernet
Configures each port independently for the
following parameters:
• Enable/disable
DHCP
• IP address, gateway, subnet mask and Ethernet
speed
• MTU
• Add a VLAN ID and name or delete a VLAN
configuration
Remote Management
Sends information about the operation of the
iPBridge to an E-Mail address using an intranet or
the Internet, or to an IP address using SMNP. You
may designate the person receiving notification of
conditions and the level of severity which prompt
notification.
Refer to
SCSI
Configures each port independently for the
following parameters:
• Bus
speed
• Enable/disable sync transfer, wide transfer, bus
reset on startup or bus termination
• Initiator
ID
• Maximum LUNs for each SCSI target
• Reset
each
port
• A link takes you to a list of attached devices.
Mapping
Allows you to create NDMP names, then assign
each name to each SCSI port or allow the
FastStream NDMP 4600 to automatically map
NDMP devices.
Refer to
Bridge
Defines a name for the FastStream NDMP 4600,
sets an admin user name and password, a read
only user name and password, restores defaults or
configures the following parameters:
• Minimum and maximum operating temperature
• Operating
temperature
warning
• Enable/disable
identifying this particular
FastStream NDMP 4600