Flex 2JB-VRX Instruction Manual
June 2022 v1.0
Page 66 of 70
6.10 System Status Light Indications
6.10.1 Transmitter Status Indications
Type
Display Type
Indication
1
Constant red
Voltage below 3.8V at initial power on
(change batteries suggested)
2
Slow red blinks
Voltage below 3.7V during operation
(change batteries suggested)
3
Constant red
Voltage below 3.6V during operation
(change batteries suggested)
4
Constant red
→
off
Voltage below 3.5V during operation
(receiver MAIN relays shut off)
5A
2 red blinks
Defective button, switch, joystick or lever
internal contact detected at initial
transmitter power on.
5B
No light displayed
When defective internal contact condition
occurs per type 5A above, find out which
internal contact is defective by initiating all
buttons, switches, joysticks and levers one
at a time. The Status LED shuts off if the
internal contact is in good working order.
The Status LED maintain 2 red blinks if
the internal contact is defective.
6
3 red blinks
Zero-G sensor triggered, receiver MAIN
relay deactivated.
7
4 red blinks
Transmitter is unable to lock onto the
assigned channel
8
Constant green for up to
2 seconds
Transmitter power on with no faults detected
9
Blinking green
Transmission in progress
10
Blinking orange
Initating any transmitter command prior to
pressing the START button at power on
11
3 slow red blinks
→
off
STOP button pressed down
12
4 orange blinks
Transmitter on standby
13
2 orange blinks
Receiver MAIN relays jammed or defective
14
3 orange blinks
Decoding processors defective
15
Constant orange when START
button is pressed at initial
system startup
Receiver MAIN relays activated