Flex 2JB-VRX Instruction Manual
June 2022 v1.0
Page 29 of 70
4.1.10 Display Frequency Band
1) Reset the STOP button (Status LED turned green for up to 2.0 seconds, transmitter
power on).
2) Press and hold both PB5 and PB6 at the same time for up to
3.0 seconds (Staus LED blinks orange). Let go of both PB5
and PB6 when LED-A and LED-B turned red.
3) Entered programming mode with Status LED displays 1x
orange blink for firmware version, remote pairing and IR
programming. 2x orange blinks for transmitter channel
programming, 3x orange blinks for PB1~PB7 function
programming,
4x orange blinks for frequency range
indication
, 5x orange blinks for TAC programming.
4) Select frequency range indication (Status LED 4x orange blinks) by press and hold
PB6 for up to 3.0 seconds four times (LED-B turned red). Let go PB6 when Status
LED turns to 4x orange blinks.
5) Enter frequency range indication mode by press and hold both PB5 and PB6 at the
same time for up to 3.0 seconds (LED-A and LED-B turned red). Let go of both PB5
and PB6 when Status LED dispays the transmitter frequency band with orange,
green and red blinks. An orange blink represents the hundreds (+
1
00), a green
blink represents the tens (+0
1
0) and a red blink represents the units (+00
1
). For
example,
8
orange blinks followed by
6
green blinks and
3
red blinks is
8
6
3
MHz.
6) Exit frequency range indication mode by pressing down the STOP button (transmitter
power off).
4.1.11 Input and Output Feedback Settings
Up to 2 assignable relay outputs or 2 external inputs can be programmed into the system and
feedback to the transmitter LED indicators during operation. These settings require using the
IR programmer unit. Please contact ARC representative for more details.
4.1.12 Infrared Function Settings
The transmitter is embedded with infrared sensors for infrared start function. These settings
require using the IR programmer unit. Please contact ARC representative for more details.
4.1.13 Zero-G Sensor Settings
The transmitter is embedded with a Zero-G sensor to guard against any unintended control of
the crane or equipment when transmitter is thrown or dropped. When triggered, the receiver
MAIN relays are deactivated with the exception of the horn output that can be assigned to any
of the Function output relays (K25, K26 or K30). This horn output setting requires the IR
programmer unit. Zero-G sensor trigger delay can also be set to either 0.5 second or 1.0
second. Please contact ARC representative for more details.
Dipswitch
Settings
Function
1
xxxxxx
0
x
Sensor Disabled
2
xxxxxx
1
x
Sensor Enabled
PB5
PB6