Flex 2JB-VRX Instruction Manual
June 2022 v1.0
Page 45 of 70
A V
4.2.6.16 Joystick LX Axis and Lever L1 Analog Output Programming
Please refe to section 4.2.3.2 for various types of analog output configurations.
1) Press the ENTER button to enter analog output type setting (cursor shown next
to VOLTAGE, CURRENT or OFF).
2) Press the UP/DOWN buttons and then the ENTER button to scroll and select between
Voltage Outputs, Current Outputs or Off (analog outputs disabled).
Voltage Outputs:
3) Press the UP/DOWN buttons and then the ENTER button to scroll and select
between Minimum, Neutral and Maximum voltage outputs (cursor shown under the
first digit to the far left). Press the UP/DOWN buttons to scroll and select voltage
value, and then the ENTER button to go to the next digit to the right. Press the
ENTER button repeatedly to cycle through the 3-digit voltage value. Press the
UP/DOWN buttons to change value.
4) Press the BACK button to return to step #3 above. Press it again to go back to
step #1. Press it again to go back to LX or L1 Analog Output Programming
(cursor shown next to LX or L1).
5) Press the UP/DOWN buttons to scroll through other system settings.
* Make sure the selector switch on analog module is set to “V” position
for voltage outputs.
Current Outputs:
6) Press the UP/DOWN buttons and then the ENTER button to scroll and select
between Minimum, Neutral and Maximum current outputs (cursor shown next to the
2-digit current value). Press the UP/DOWN buttons to scroll and select current
output value.
7) Press the BACK button to return to step #6 above. Press it again to go back to step
#1. Press it again to go back to LX or L1 Analog Output Programming (cursor
shown next to LX or L1).
8) Press the UP/DOWN buttons to scroll through other system settings.
* Make sure the selector switch on analog module is set to “A” position
for current (amperage) outputs.
>LX or L1
>VOLTAGE
ANALOG
MAX 10.0V
NEU 00.0V
MIN 10.0V
UP DOWN ENTER BACK
>LX or L1
>CURRENT
ANALOG
MAX 20mA
NEU 00mA
MIN 20mA
UP DOWN ENTER BACK
>LX or L1
>OFF
ANALOG
UP DOWN ENTER BACK
A V
Содержание FLEX 2JB-VRX
Страница 1: ...FLEX2JB VRX Instruction Manual ...