4.1.7 Infrared (IR) Programming
Other transmitter functions and settings not listed in this manual can be programmed via the
IR programmer unit, such as the system serial number, frequency range, TAC, relay output
status feedback, receiver input status feedback, infrared start function, buttons and switches
configurations and many others. Please contact ARC representative for more details.
1) Reset the STOP button (Status LED turned green for up to 2.0 seconds, transmitter
power on).
2) Press and hold both PB5 and PB6 at the same time for up to 3.0 seconds (Staus LED
blinks orange). Let go of both PB5 and PB6 when LED-A and LED-B turned red.
3) Entered programming mode with Status LED displays 1x orange blink for firmware
version, remote pairing and
IR programming
. 2x orange blinks for transmitter
channel programming, 3x orange blinks for PB1~PB7 button function programming,
4x orange blinks for frequency range indication, 5x orange blinks for TAC
programming.
4) Press and hold both PB5 and PB6 at the same time for up to 3.0 seconds (LED-A and
LED-B turned red). Let go of both PB5 and PB6 when Status LED turned orange.
5) The Status LED now displays the transmitter firmware version with red, green and
orange blinks.
6) Proceed to infrared transmitter programming using the IR programmer unit.
7) Exit infrared programming mode by pressing down the STOP button (transmitter power off).
PB5