Flex 2JB-VRX Instruction Manual
June 2022 v1.0
Page 60 of 70
f.
After 5 minutes of transmitter inactivity, the receiver MAIN relays are temporarily
disconnected (refer to section 4.1.5 Inactivity Timer Settings). The Status LED blinks
3 reds and then shuts off. Press the START button to reactivate the receiver MAIN
relays and resume operation (refer to section 4.1.4 Start Function Settings).
g.
Turn off the transmitter power by pressing down the STOP button; it will disconnect
the transmitter power and the receiver MAIN relays altogether.
6.2 Master/Master Tandem Operation (Tandem models)
a.
To gain control of one or both receivers, first move
the 3-position rocker switch to either A, B or A+B
position and then press the START button to
activate the receiver MAIN relays inside receiver A,
receiver B, or both receivers (depending on the
rocker switch position). In order to gain control of a
receiver, the PITCH button on the other transmitter
must be pressed prior to your takeover. For
example, in order for transmitter-A to gain control of
receiver-B, transmitter-B must first release its
control of receiver-B by first move the rocker switch
to B position and then press the PITCH button for
up to 2.0 seconds. This action releases transmitter-
B control of receiver-B. Transmitter-A is then able
to take control of receiver-B by first move the rocker
switch to B position and then press the START button. Make sure the START
command is executed 2.0 seconds after transmitter-B presses the PITCH button
(refer to diagram below).
Master Transmitter-A Takeover Procedure
Move to B position Press PITCH
Move to B position
Press START
→
→
→
(After 2 seconds)
Transmitter-B
Transmitter-B
Transmitter-A Transmitter-A
Содержание FLEX 2JB-VRX