Flex 2JB-VRX Instruction Manual
June 2022 v1.0
Page 32 of 70
4.2.2.2 Non-Interlocking Button Outputs
Non-interlocking button pair or adjacent button
can be pressed simultaneously. It usually
applies to equipment’s auxiliary functions such
as lights, horn or buzzer. Refer to section 4.2.1
and section 4.2.6.13 ~ 4.2.6.15 output
descriptions and programming.
Function #
Function Descriptions (left button / right button)
# of Relays
Used
10000000
Normal / Normal
2
10000010
Normal / Toggled
2
10000110
Normal / Toggled (EMS)**
2
10001000
Normal / Start*
2
10001100
Normal / Pitch & Catch
2
10010000
Toggled / Normal
2
10010010
Toggled / Toggled
2
10010110
Toggled / Toggled (EMS)**
2
10011000
Toggled / Start*
2
10011100
Toggled / Pitch & Catch
2
10110000
Toggled (EMS**) / Normal
2
10110010
Toggled (EMS)** / Toggled
2
10110110
Toggled (EMS)** / Toggled (EMS)**
2
10111000
Toggled (EMS)** / Start*
2
10111100
Toggled (EMS)** / Pitch & Catch
2
11000000
Start* / Normal
2
11000010
Start* / Toggled
2
11000110
Start* / Toggled (EMS)**
2
11001000
Start* / Start*
2
11001100
Start* / Pitch & Catch
2
11100000
Pitch & Catch / Normal
2
11100010
Pitch & Catch / Toggled
2
11100110
Pitch & Catch / Toggled (EMS)**
2
11101000
Pitch & Catch / Start*
2
* Start: For added safety, you must first press and hold the green START button and then the
intended button to activate the output relay.
** EMS: Relay opens when STOP button is pressed down.