CFS100 SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS100 Series Power Source Operation Manual
Page 97 of 146
6.16
DC Mode Operation
To select DC mode of operation, make sure the output is OFF first. Changing mode is not
possible while the output is active.
From the top level Menu, select the “
System
” soft key. This brings up the System menu. The
selected operating mode will be shown in the top left field as the first parameter entry.
6.16.1
Available Parameters in DC Mode
In DC mode, the following System parameters can be set from this screen:
•
Mode
•
Alarm Volume
•
Contrast of LCD Display
•
Power Up Mode
•
Voltage High Limit
•
Voltage Low Limit
•
Results display Mode
•
Over Current Protection Fold Back mode
•
Lock Mode
•
Memory Lock Mode
6.16.2
Programming DC mode parameters
Programming in DC mode is similar to programming steps in MANUAL mode except for DC
output instead of AC output. There is no Frequency setting, no start and stop phase angles,
no peak current or power factor measurement. For details on setting any of the DC Mode
parameters that are in common with AC mode listed above, refer to the corresponding in
Section 6.12, “PROGRAM Mode - Step Parameter Details”.
Note that the 50 memories to store a DC mode setup and select the Memory location to use
from, are still available in this mode. There are just no Steps in this mode of operation and
step specific parameters like Dwell, Delay, Ramp-Up, Ramp-Down etc.