WARNING
A small plastic cover is mounted on both the Output and Input
terminal block. This is
NOT A SAFETY
cover. The full safety cover
supplied in the shipkit
MUST
be used at all times
5.11.1
REMOTE OUTPUT Connecter
All CFS100 models have a blue DB9 status output connector (Female). Do not confuse this
connector with the black male DB9 connector for the RS232 interface.
The rear panel REMOTE OUTPUT connector provides output signals to remotely monitor
PASS, FAIL, and PROCESSING conditions. When a terminal becomes active the relay closes
thereby allowing the external voltage to operate an external device. The following table
provides the conditions of each pin and the relay state.
Condition
Pins
Relay State
PASS
Connection between PIN
1 & PIN 2
Closes on PASS and
is opened on next test
initialized
FAIL
Connection between PIN
3 & PIN 4
Closes on FAIL and is
opened when next test
is initialized
PROCESSING
Connection between PIN
5 & PIN 6
Closes when test initialized
and opens after test is
completed
Table 5-9: REMOTE OUTPUT CONNECTOR Pins