6.12.9
Step Cycle Programming
To program the Step Cycle settings, use the “
∧
and
∨
” soft keys to navigate to the Step Cycle
parameter. Pressing the “
Edit
” soft key will display the screen shown below.
The Step Cycle determines how often each step in a sequence of steps is repeated. The
default value is one (1) which means each step is executed only once (not repeated). A
value of zero (0) indicates the step is executed continuously until manually stopped by the
operator. Any other value determines the number of time each step is executed before
advancing to the next step. This is similar to the Loop Cycle parameter as covered in Section
6.10.7 except the Loop Cycle applies to complete Memory (all steps) while the Step Cycle
setting applies to individual steps and is only available in PROGRAM mode.
Thus for a given setting <n>:
•
1 =
Step will run once
•
0 =
Step will run continuously until manually stopped by operator
•
2-9999 = Step will run <n> times
Use the numeric keypad to enter in the Step Cycle setting. Press the “
Enter
” soft key to
accept the parameter. To cancel editing, press the “
Esc
” soft key.
6.12.10
Connect Mode Programming
The Connect function allows a step to link to another step rather than the next step number.
This allows the user to execute steps out of sequence if needed.
To program the Connect mode setting, use the “
∧
and
∨
” soft keys to navigate to the
Connect parameter. Pressing the “
Edit
” soft key will display the screen shown below.
Press the “
Change
” soft key to toggle the connect mode ON or OFF. To save the parameter
setting, press the “
Enter
” soft key. To cancel the editing of the step mode press the “
Esc
”
Содержание CFS108