CFS100 SERIES OPERATION MANUAL
SECTION 7: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS100 Series Power Source Operation Manual
Page 106 of 146
Command
Description
Value
Unit
SAG <value>
Set Start Angle
0-359
SAG?
Return Start Angle
0-359
EAG <value>
Set End Angle
0-359
EAG?
Return End Angle Value
0-359
Table 7-2: Parameter Setup Command and Query Summary
7.6
System Command and Query Syntax
These commands are used to modify the system parameters for the instrument. These
commands require a parameter value to be included with the command. The associated
query version of these commands will return the parameter setting in effect.
Command
Description
Value
Unit
OM X
Output Mode 0 | 1
0 = AC, 1 = DC
OM?
Return Output Mode
0-1
SS {1|0}
Set Single Step
0=OFF,1=ON
SS?
Return Single Step
0-1
ALARM <value>
Set Alarm Volume
1-9, 0=OFF, 9=high
ALARM?
Return Alarm Volume
0-9
CONTRAST
<value>
Set Contrast
1-9, 1= low, 9=high
CONTRAST?
Return Contrast
1-9
PUP {2|1|0}
Set Power Up Command
0=OFF,1=ON,2=LAST
PUP?
Return Power Up Value
0-2
LC <value>
Set Loop Cycle Value
0-9999 ,0=Cont,1=OFF
LC?
Return Loop Cycle Value
0-9999
VHI <value>
Set Voltage High Limit
0.0-300.0
V
VHI?
Return Voltage High Limit
5.0-300.0
V
VLO <value>
Set Voltage Low Limit
5.0-300.0
V
VLO?
Return Voltage Low Limit
5.0-300.0
V
FHI <value>
Set Frequency High Limit
45.0-500.0
Hz
FHI?
Return Frequency High Limit
45.0-500.0
Hz
FLO <value>
Set Frequency Low Limit
45.0-500.0
Hz
FLO?
Return Frequency Low Limit
45.0-500.0
Hz