4.5
Metering – DC Mode
MEASUREMENT SPECIFICATIONS -DC MODE
MODEL
CFS108
CFS116
CFS140
Voltage DC
Range
0.0 - 400.0 Vdc
Accuracy
± ( 0.2% S 0.3V )
Current DC
Range
0.05-6.5Adc
0.05-13.0Adc
0.05-26.0Adc
Accuracy
± ( 1.0% S 0.05 Adc )
Power
Range
0 - 1300 W
0 - 2600 W
0-5200 W
Accuracy
±(2% Rdg+1.5W
±(2% Rdg+3W)
±(2% Rdg+5W)
4.6
Protection Modes
PROTECTION MODES
Available Modes
Over Temperature
Heatsink temperature exceeds 130° C. Test/Reset LED blinks.
Over Voltage
Trips when output voltage exceeds 155V on 150V range or 310V
on 300V range. Test/Reset LED blinks.
Over Current Fold-back
Fold back of voltage when load current exceeds set current limit
value. Test/Reset LED blinks.
Over Current Trip
Trips when load current exceeds 110% of maximum output
current rating for 1 second or there is a short-circuit at the
output for more than 6 seconds.
Over Power
Trip when output power exceeds 110% of maximum rated power
for more than 1 second. Test/Reset LED blinks.
Low Voltage Protection
Trips when output voltage is more than 10V different from the
voltage set point and over current fold back is not in effect.
Test/Reset LED blinks.
Amplifier Shutdown
Trips if the output amplifier is in an abnormal condition.
Test/Reset LED blinks.