CFS100 SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS100 Series Power Source Operation Manual
Page 94 of 146
6.14
MANUAL (AC) Mode Operation
To select MANUAL mode of operation, make sure the output is OFF first. Changing mode is
not possible while the output is active.
From the top level Menu, select the “
System
” soft key. This brings up the System menu. The
selected operating mode will be shown in the top left field as the first parameter entry.
6.14.1
Available Parameters in MANUAL Mode
In MANUAL mode, the following System parameters can be set from this screen:
•
Auto Run Mode
•
Alarm Volume
•
Contrast of LCD Display
•
Power Up Mode
•
Voltage High Limit
•
Voltage Low Limit
•
Frequency High Limit
•
Frequency Low Limit
•
Start Phase Angle
•
End Phase Angle
•
Results display Mode
•
Surge/Drop Mode
•
Over Current Protection Fold Back mode
•
Lock Mode
•
Memory Lock Mode
6.14.2
Programming MANUAL mode parameters
Programming in MANUAL mode is similar to programming steps in PROGRAM mode except
there is no step number to select as there is effectively only one “step” or setting. For
details on setting any of the MANUAL Mode parameters listed above, refer to the
corresponding in Section 6.12, “PROGRAM Mode - Step Parameter Details”.
Note that the 50 memories to store a MANUAL mode setup and select the Memory location
to use from, are still available in this mode. There are just no Steps in this mode of
operation and step specific parameters like Dwell, Delay, Ramp-Up, Ramp-Down etc.
However, features like Start and Stop phase angles, Voltage Surge/Drop are still available.