5.6.3
CFS108 Models
The CFS108 model power source can be ordered configured for either 115V or 230V AC
input configurations. Prior to connecting the CFS108, verify the local mains’ setting matches
the type label on the unit to verify the AC input configuration matches the local utility
power. If not, slide the RED voltage selection switch to the position that matches your local
utility.
Do not connect any CFS100 Series unit to the mains if the AC input voltage, phasing and
frequency does not match.
Figure 5-6: AC Input Voltage Selector Switch Location CFS108
5.6.4
CFS116 & CFS140 Models
The CFS160 and CFS140 are available with either 208V or 230V ac single phase input. 208V
models may be connected to a 208V three phase power connection by using two of the
three phase. The 230V models may be also used with a split-phase 230V ac line. The
configured AC input is shown on the rear panel directly to the right of the C20 AC inlet
connector as shown below.
Do not attempt to operate the CFS140 from a 115V AC outlet.
Table 5-4: AC Input Voltage Identification Location CFS116
Note:
Models CFS108 and CFS116 are fitted with a mains input fuse located on the rear
panel. A spare fuse is included in the ship kit. If any of these need to be replaced,
please contact customer service.