CFS100 SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS100 Series Power Source Operation Manual
Page 32 of 146
4.8
System Parameters
SYSTEM PARAMETERS
Operating Modes
Program Mode, Manual Mode
Single Step Mode
On / Off selectable
Alarm Level
0 through 9, 0 = OFF, 9 = HIGH
LCD Contrast
0 through 9, 0 = OFF, 9 = HIGH
Power Up Settings
Output OFF, Output ON or LAST
Timer
Seconds, Minutes, Hours
Loop Cycle
0 - 9999, 0 = Cont. 1 = OFF
Voltage Surge/Drop
ON, OFF
Over Current Fold-back
ON, OFF
4.9
Test Mode Parameters
TEST MODE PARAMETERS
Memories
1 through 50
Steps / Memory
1 through 9
Memory Cycling
0 - 9999, 0 = Cont., 1 = OFF
Test Limits
Frequency, Current Hi/Lo, Power Hi/Lo, App. Power Hi/Lo, PF
Hi/Lo
Ramp Up or Down
0.0 - 999.9
Delay
0.5 - 999.9
Dwell
0.5 - 999.9
Step Cycles
0 - 9999, 0 = Cont., 1 = OFF
Connect
ON, OFF
Surge / Drop Voltage
ON: Start 0-20ms, Duration 0-20ms
OFF: Start 0-99ms, Duration 0-99ms