CFS100 SERIES OPERATION MANUAL
SECTION 7: REMOTE PROGRAMMING
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS100 Series Power Source Operation Manual
Page 105 of 146
Command
Description
Value
Unit
PLO?
Return Power Low Limit
0.0~5000
W
PFHI <value>
Set Power Factor High Limit
0.000~1.000
PFHI?
Return Power Factor High Limit
0.000~1.000
PFLO <value>
Set Power Factor Low Limit
0.000~1.000
PFLO?
Return Power Factor Low Limit
0.000~1.000
RAMPUP
<value>
Set Ramp Up Timer
0.1~999.9
s
RAMPUP?
Return Ramp Up Timer
0.1~999.9
s
TUNIT {2|1|0}
Set Time Unit
0=Second,1=Minute,2=Hour
TUNIT?
Return Time Unit
0-2
DELAY <value>
Set Delay Timer
0.1~999.9
s/m/h
DELAY?
Return Delay Timer
0.1~999.9
s/m/h
DWELL <value>
Set Dwell Timer
0.0~999.9 ,0=Const
s/m/h
DWELL?
Return Dwell Timer
0.0~999.9
s/m/h
RAMPDOWN
<value>
Set Ramp Down Timer
0.1~999.9
s
RAMPDOWN?
Return Ramp Down Timer
0.1~999.9
s
SDVOLT <value>
Set Surge Drop Voltage
0.0~300.0
V
SDVOLT?
Return Surge Drop Voltage
0.0~300.0
V
SDLT <value>
Set Surge Drop Site
0.0~99.9
ms
SDLT?
Return Surge Drop Site
0.0~99.9
ms
SDHT <value>
Set Surge Drop Time
0.0~25.0
ms
SDHT?
Return Surge Drop Time
0.0~25.0
ms
SDCT {1|0}
Set Surge Drop Mode
0=OFF,1=ON
SDCT?
Return Surge Drop Mode
0~1
PTD
Delete Prompt
PT <value>
Create Prompt
1-30 BYTES of information
PT?
Return Prompt String
SC <value>
Set Step Cycle Value
0-9999, 0=Cont,1=OFF
SC?
Return Step Cycle Value
0-9999
CONNECT {1|0}
Step Connect
0=OFF,1=ON
CONNECT?
Return Step Connect
0 | 1