5.9 USB Link Sequence Setup Screen (With Option 012 Installed)
5-69
5
R
em
ot
e C
on
trol
:SENSe:MEASure:BER:ECTHreshold?
Response
<numeric>=<NR1 NUMERIC RESPONESE DATA>
0 to 1000
0 to1000
Function
Queries the evaluation threshold of the BER measurement.
Example
>:SENSe:MEASure:BER:ECTHreshold?
< 1
:SENSe:MEASure:BER:MODE <mode>
Parameter
<mode>=<CHARACTER PROGRAM DATA>
SINGle
Performs the measurement once.
REPeat
Performs the measurement repeatedly.
Function
Sets the measurement processing mode for the BER measurement.
Example
To set the measurement processing mode for the BER measurement to
Repeat:
> :SENSe:MEASure:BER:MODE REPeat
:SENSe:MEASure:BER:MODE?
Response
<mode>=<CHARACTER PROGRAM DATA>
SING, REP
Function
Queries the measurement processing mode for the BER measurement.
Example
>:SENSe:MEASure:BER:MODE?
< REP
:SENSe:MEASure:BER:TIMe <numeric>
Parameter
<numeric>=<DECIMAL NUMERIC PROGRAM DATA>
1 to 100
1 to 100 s/1s step
Function
Sets the Gaiting Time of the USB BER measurement.
Example
To set the Gaiting Time of the USB BER measurement to 6 s:
>:SENSe:MEASure:BER:TIMe 6
:SENSe:MEASure:BER:TIMe?
Response
<numeric>=<NR1 NUMERIC RESPONSE DATA>
1 to 100
Function
Queries the Gaiting Time of the USB BER measurement.
Example
>:SENSe:MEASure:BER:TIMe?
< 6
Содержание MX183000A
Страница 12: ...xii ...
Страница 16: ...IV ...
Страница 20: ...Chapter 1 Outline 1 4 Figure 1 1 3 Jitter Tolerance Graph Screen ...
Страница 54: ...Chapter 3 Connecting Equipment 3 16 ...
Страница 136: ...Chapter 5 Remote Control 5 30 Figure 5 8 2 Sequence Screen BER Measurement 10 8 9 11 ...
Страница 206: ...Chapter 5 Remote Control 5 100 ...
Страница 218: ...Appendix A Specifications A 12 ...
Страница 226: ...Appendix B Default Settings B 8 ...