Chapter 5 Remote Control
5-38
:LTRaining:SEQuence:DESign:REV2:RECovery <type>,<numeric>
Parameter
<type>=<CHARACTER PROGRAM DATA>
DQUite
DETECT_QUITE (wait)
DACTive
DETECT_ACTIVE
PACTive
POLLING_ACTIVE
PCONfiguration
POLLING_CONFIGURATION
CLIStart
CONFIGURATION_LINKWIDTH_START
CLIaccept
CONFIGURATION_LINKWIDTH_ACCEPT
CLAWait
CONFIGURATIONS_LANE_WAIT
CLAaccept
CONFIGURATIONS_LANE_ACCEPT
CCOMplete
CONFIGURATION_COMPLETE
CIDLe
CONFIGURATION_IDLE (wait)
RRLock1
RECOVERY_RCVR_LOCK
RRCeqts2
RECOVERY_RCVR_CFG_EQTS2
RSPeed
RECOVERY_SPEED (wait)
RRLock2
RECOVERY_RCVR_LOCK
RRCTs2
RECOVERY_RCVR_CFG_TS2
LEMaster
LOOPBACK_ENTRY_MASTER
<numeric>=<DECIMAL NUMERIC PROGRAM DATA>
1 to 1000000
1 to 1000000 cycles
TS transmission cycles per step
1 to 1000000
1 to 1000000 µs Wait time/1 µs Step
Function
Sets a sequence pattern to loopback the DUT (REV2).
Example
To set the wait for DETECT_QUITE to 100 µs:
> :LTRaining:SEQuence:DESign:REV2:RECovery DQU,100
To set the number of times POLLING_ACTIVE patterns are sent to 1024:
> :LTRaining:SEQuence:DESign:REV2:RECovery PACT,1024