Setting Program Preferences
182
NetLinx Studio (v2.4 or higher)
Preferences Dialog - Diagnostics Tab
Use the options on the Diagnostics tab of the Preferences dialog to set default diagnostics
preferences. The items in this dialog include:
Notification View
- Use this set of options to set default display preferences for the
Notification tab of the Output Display Window.
Display Line Numbers
- Toggles the display of line numbers in asynchronous
notification displays (default = enabled).
Display Time Stamp
- Toggles the display of time stamps in asynchronous
notification displays in one-second increments (default = enabled).
When enabled, the Display Milliseconds option causes asynchronous notification time
stamps to be displayed in milliseconds (default = disabled).
Display Control Codes as
- Converts unprintable characters (i.e. Control Codes)
into either Hexadecimal or Decimal values within the message (default = Hex
Values).
Diagnostics View
- Use this set of options to set default display preferences for the
Diagnostics tab of the Output Display Window.
Display Line Numbers
- Toggles the display of line numbers in system diagnostics
displays (default = enabled).
Display Time Stam
p - Toggles the display of time stamps in system diagnostics
displays in one-second increments (default = enabled).
When enabled, the Display Milliseconds option causes diagnostics time stamps to be
displayed in milliseconds (default = disabled).
Display Control Codes as
- Converts unprintable characters (i.e. Control Codes)
into either Hexadecimal or Decimal values within the message (default = Hex
Values).
Buffer File Options
- Use the text box to specify the total size of the two files that are
used by the program to buffer the asynchronous notification and system diagnostic
messages. The number specified here will be divided evenly between the two files. The
range is 2 - 500 MB (default = 10). If you have less than 500 MB free on your disk, then
the upper range value will be adjusted according to the amount of free space on your
Hex values will display with a leading $ character. For example the message:
STRING from CHANNEL 6 - $0F$1D has two control codes converted to
hexadecimal.
Decimal values will display with a leading # character:
STRING from CHANNEL 6 - #15#29.
The Line Number, Time Stamp and Control Code display options will only take affect
after you stop and then start the asynchronous notifications/diagnostics message
feeds.
Содержание NETLINX STUDIO V2.4
Страница 1: ...instruction manual Software NetLinx Studio v2 4 or higher ...
Страница 16: ...NetLinx Studio v2 4 or higher 4 NetLinx Studio v2 4 or higher ...
Страница 32: ...The NetLinx Studio v2 4 Work Area 20 NetLinx Studio v2 4 or higher ...
Страница 44: ...Working With Workspace Files 32 NetLinx Studio v2 4 or higher ...
Страница 88: ...Working With Systems and System Files 76 NetLinx Studio v2 4 or higher ...
Страница 118: ...Programming 106 NetLinx Studio v2 4 or higher ...
Страница 152: ...Working With Online Devices 140 NetLinx Studio v2 4 or higher ...
Страница 199: ...Index 187 NetLinx Studio v2 4 or higher ...