Communications and File Transfers
148
NetLinx Studio (v2.4 or higher)
If you don't connect:
Verify that the master is set for ICSP Connectivity, with Require Encryption enabled (via
the Master's built-in interface).
Refer to the Master's documentation for details on enabling/disabling security.
Connecting To an Axcess Master
To connect to an AXCESS master, use the options in the Master Communication Settings and
Communication Settings dialogs to specify the serial port or modem settings, depending on the
transport connection type specified. These instructions in these topics assume that the physical link
between the PC running NetLinx Studio and the AXCESS master is established.
Connecting To An Axcess Master Via Serial Port
To connect to an AXCESS master, use the options in the Master Communication Settings and
Communication Settings dialogs to specify the serial port or modem settings, depending on the
transport connection type specified. These instructions in these topics assume that the physical link
between the PC running NetLinx Studio and the AXCESS master is established.
1.
Select
Settings > Master Communication Settings
to open the Master Communication
Settings dialog.
2.
Click
Communication Settings
to access the Communication Settings dialog.
3.
Select
Axcess Master
as the Platform Selection.
4.
Select
Serial
as the Transport Connection Option.
5.
Click
Edit Settings
to open the Serial Settings dialog.
6.
Select a COM port and specify the communication settings for serial port communications.
The default settings are:
7.
Click
OK
to return to the Communication Settings dialog.
8.
Click
OK
to return to the Master Communication Settings dialog.
9.
Click
OK
to close the Master Communications dialog.
10.
In the online tree (displayed in the Online Tree tab of the Workspace window), click
Display
to
open the Online Tree sub-menu, and select
Refresh Network
to refresh the online tree display.
11.
Double-click the System icon to expand the tree to show the Axcess master.
Connecting To An Axcess Master Via Modem
To connect to an AXCESS master, use the options in the Master Communication Settings and
Communication Settings dialogs to specify serial port or modem settings, depending on the
Comm Port
COM1
Baud Rate
38400
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
Содержание NETLINX STUDIO V2.4
Страница 1: ...instruction manual Software NetLinx Studio v2 4 or higher ...
Страница 16: ...NetLinx Studio v2 4 or higher 4 NetLinx Studio v2 4 or higher ...
Страница 32: ...The NetLinx Studio v2 4 Work Area 20 NetLinx Studio v2 4 or higher ...
Страница 44: ...Working With Workspace Files 32 NetLinx Studio v2 4 or higher ...
Страница 88: ...Working With Systems and System Files 76 NetLinx Studio v2 4 or higher ...
Страница 118: ...Programming 106 NetLinx Studio v2 4 or higher ...
Страница 152: ...Working With Online Devices 140 NetLinx Studio v2 4 or higher ...
Страница 199: ...Index 187 NetLinx Studio v2 4 or higher ...