File Transfer Operations
209
TPDesign4 Touch Panel Design Software (v2.10 or higher)
Otherwise, create and save a serial communication configuration via the Connection Settings
dialog:
a.
In the
Name
field, enter a name for this communication configuration. This is the name that will
appear in the drop-down list of the Connect dialog.
b.
Select
Serial
from the
Transport
drop-down list.
c.
Configure the selected serial (COM port) connection (
Baud Rate, Data Bits, Parity, Stop Bits
and
Flow Control
).
The suggested settings are:
d.
Click
OK
to save the configuration and close the Connection Settings dialog
2.
Click
Connect
in the Connect dialog to establish the serial connection.
3.
Once communication is established, either the Send To Panel or Receive From Panel dialog is
invoked (depending on wether you selected
Send to Panel
or
Receive From Panel
from the Transfer
menu), displaying an online device tree, indicating all devices connected to the Master that are
currently online (according to the Filter setting). The online device tree lists the online devices by
System #, Device #, Description, (firmware) Version, and Manufacturer.
4.
Use the
Options
checkboxes in the Send to Panel or Receive From Panel dialog to enable/disable
the following transfer options:
Smart transfer (updated panel files only)
: Select to utilize the Smart Transfer feature, which
reduces the transfer time by only replacing those panel files that have been updated (relative to
the files already loaded in the panel). Any bitmaps, sound files and fonts that all already
resident on the target panel, or in your panel file on your PC (for uploads) are not included in
the transfer.
Normal transfer (all panel files)
: This option sends all panel files.
Full clean transfer (all panel & system graphic files)
: Select this option to automatically
wipe out any existing project files resident in the target panel before loading the new panel
file.
Open received panel (uploads only)
: Select this option to automatically open the panel file
once it is received.
• Baud Rate
38400
• Data Bits
8
• Parity
none
• Stop Bits
1
• Flow Control
none
These settings must match those of the selected COM port.
To refresh the Online Devices Tree, disconnect and reconnect via the commands in
the Transfer menu.
If you are simply sending a panel file to a panel, you don't need to use the Full Clean
option, since any existing panel files on the target panel will be wiped out anyway.
The Full Clean option adds considerable time to the transfer, since it involves sending
many more files, and is not necessary in most cases.
Содержание Modero NXD-1200VG
Страница 20: ...xviii TPDesign4 Touch Panel Design Software v2 10 or higher Table of Contents ...
Страница 130: ...List Box Buttons 110 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 160: ...Working With States 140 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 166: ...Working With Function Codes 146 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 174: ...Colors and Palettes 154 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 186: ...Animations and Tweening 166 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 208: ...Working With Templates 188 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 236: ...File Transfer Operations 216 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 248: ...Program Preferences 228 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 266: ...Appendix B G4 PanelBuilder 246 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 272: ...Appendix C TakeNote 252 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 273: ...Appendix C TakeNote 253 TPDesign4 Touch Panel Design Software v2 10 or higher ...