File Transfer Operations
212
TPDesign4 Touch Panel Design Software (v2.10 or higher)
Powering Up and Connecting the Panel
1.
Verify that an Ethernet cable is connected from either the rear (NXT models) or side (NXD models)
of the panel to a valid Ethernet Hub.
2.
Connect the terminal end of the PSN6.5 power cable to the 12 VDC power connector on the rear/
side of the touch panel.
3.
Verify the green Ethernet LED (from the rear Ethernet port) is illuminated (to indicate a proper
connection).
Configuring the Touch Panel for Virtual NetLinx Master TCP/IP Transfers
If it is not already powered up and connected, apply power to the touch panel and verify that it is
connected to the LAN via the TCP/IP connector on the rear (or side) of the panel (G4 panels only).
To configure the panel for Virtual NetLinx Master transfers:
1.
Press and hold the grey Front Setup Access button (below the touch screen) for 3 seconds to access
the Setup page.
2.
Press the
Protected Setup
button to access the Protected Setup page.
3.
Use the on-screen keyboard to enter the password (the default password is
1988
).
4.
Press the
System Connection
button to access the System Connection Setup page.
5.
Select
Ethernet
as the
Master Connection
.
6.
Select
URL
as the
Connection Mode
.
7.
Set the
System Number
to
0 (zero)
.
8.
Select the
Master URL / IP
input box and enter the IP address of your PC (displayed in the Virtual
NetLinx Master Properties dialog).
9.
Press the
Back
button to return to the Protected Setup page and press the
Reboot
button to reboot
the panel.
10.
After several seconds, the panel should appear in the online device tree, listed as Virtual NetLinx
Master. Once you can see the device online, you may transfer panel files to and from the G4 device
without the need for an intermediate NetLinx master.
Transferring Files Using a Virtual NetLinx Master TCP/IP
Connection
Once you have configured both the touch panel and TPDesign4 for Masterless TCP/IP Transfers, you are
ready to transfer files to/from the panel without the need for an intermediate master:
Sending Files To the Panel
1.
Select
Transfer > Send to Panel
to open the Send to Panel dialog.
2.
Select any Options (
Smart Transfer, Normal Transfer
or
Full Clean
) as desired.
3.
Click the
Send
button to initiate the transfer. The progress of the transfer is indicated in the Status
column of the Transfer Status Window.
Allow several seconds after the panel is rebooted for it to appear in the Online Device
list in the Send To Panel or Receive From Panel dialogs.
Содержание Modero NXD-1200VG
Страница 20: ...xviii TPDesign4 Touch Panel Design Software v2 10 or higher Table of Contents ...
Страница 130: ...List Box Buttons 110 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 160: ...Working With States 140 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 166: ...Working With Function Codes 146 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 174: ...Colors and Palettes 154 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 186: ...Animations and Tweening 166 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 208: ...Working With Templates 188 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 236: ...File Transfer Operations 216 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 248: ...Program Preferences 228 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 266: ...Appendix B G4 PanelBuilder 246 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 272: ...Appendix C TakeNote 252 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 273: ...Appendix C TakeNote 253 TPDesign4 Touch Panel Design Software v2 10 or higher ...