File Transfer Operations
214
TPDesign4 Touch Panel Design Software (v2.10 or higher)
Transferring Files Using a Virtual NetLinx Master USB
Connection
Once you have configured both the touch panel and TPDesign4 for Masterless USB Transfers, you are
ready to transfer files to/from the panel without the need for an intermediate master:
Sending Files To the Panel
1.
Select
Transfer > Send to Panel
to open the Send to Panel dialog.
2.
Select any
Options
(
Smart Transfer
,
Normal Transfer
or
Full Clean
) as desired.
3.
Click the
Send
button to initiate the transfer. The progress of the transfer is indicated in the
Status
column of the Transfer Status Window.
Receiving Files From The Panel
1.
Select
Transfer > Receive
from Panel to open the Receive from Panel dialog.
2.
Select any
Options
(
Smart Transfer
,
Normal Transfer
or
Full Clean
) as desired.
3.
Click the
Receive
button to initiate the transfer. The progress of the transfer is indicated in the
Status
column of the Transfer Status Window.
Sending a Project Without Opening the File
Select
Transfer > Send To Panel
(or
Transfer > Send File To Panel
) to send a panel file to a NetLinx
Master with a G4-compatible panel (or panels) on its bus. There are three transport types available to
transfer touch panel files: TCP/IP, Serial and Modem.
TP4 touch panel files are transferred to the NetLinx Master that the target panels are connected, rather
than directly to the panels. In order to transfer touch panel files, you must first establish communication
between the PC and the NetLinx Master, via the Connect dialog. Connections are maintained separate
from the transfer itself, so they do not need to be established/dropped each time a transfer is performed.
Use the
Connect
dialog to define and save connection settings.
Transfer Status Window
The Send To Panel and Receive From Panel dialogs place the requested transfer into a queue, the status
of which is displayed in the Transfer Status window, which may be docked/undocked from the main
application window. This window displays the following data for each transfer:
Status
: The status bars indicate the progress of each file in the transfer, and the overall status
of the transfer.
Device
: This column gives the Device # and a description of the target/source device.
Project
: This column indicates the name of the Project the files belong to.
Transfer Status Context Menu
Right mouse click anywhere in the Transfer Status Window to open the Transfer Status context menu,
containing options for establishing a connection to the NetLinx Master and panels, and for transferring
TP4 files to the panels.
Note that this context menu is identical to the Transfer Menu, accessible through the main menu bar.
Use the
Send File To Panel
option to send a project file without having to open it in
TPDesign4.
Содержание Modero NXD-1200VG
Страница 20: ...xviii TPDesign4 Touch Panel Design Software v2 10 or higher Table of Contents ...
Страница 130: ...List Box Buttons 110 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 160: ...Working With States 140 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 166: ...Working With Function Codes 146 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 174: ...Colors and Palettes 154 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 186: ...Animations and Tweening 166 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 208: ...Working With Templates 188 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 236: ...File Transfer Operations 216 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 248: ...Program Preferences 228 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 266: ...Appendix B G4 PanelBuilder 246 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 272: ...Appendix C TakeNote 252 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 273: ...Appendix C TakeNote 253 TPDesign4 Touch Panel Design Software v2 10 or higher ...