File Transfer Operations
210
TPDesign4 Touch Panel Design Software (v2.10 or higher)
Clear from status queue when complete
: This option (enabled by default) clears each
transfer from the Transfer Status Window when complete.
5.
Click
Send
or
Receive
to begin the transfer.
Panel File Transfers via Modem
In TPDesign4, file transfer operations are typically routed through the Master to which the target/source
touch panels are connected. To use a Modem as the transport type:
1.
Select
Transfer > Send to Panel
or
Receive From Panel
. If you are not already connected to the
Master, the Connect dialog is invoked.
If you have already established a modem communication configuration, select it from the drop-
down list.
Otherwise, create and save a modem communication configuration via the Connection Settings
dialog:
a.
In the
Name
field, enter a name for this communication configuration. This is the name that will
appear in the drop-down list of the Connect dialog.
b.
Select
Modem
from the
Transport
drop-down list.
c.
Configure the selected modem connection (
Baud Rate, Data Bits, Parity, Stop Bits, Flow
Control
and
Phone Number
).
The suggested settings are:
d.
Click
OK
to save the configuration and close the Connection Settings dialog
2.
Click
Connect
in the Connect dialog to establish the modem connection.
3.
Once communication is established, either the Send To Panel or Receive From Panel dialog is
invoked (depending on wether you selected Send to Panel or Receive From Panel from the Transfer
menu), displaying an online device tree, indicating all devices connected to the Master that are
currently online (according to the Filter setting). The online device tree lists the online devices by
System #, Device #, Description, (firmware) Version, and Manufacturer.
4.
Use the
Options
checkboxes in the Send to Panel or Receive From Panel dialog to enable/disable
the following transfer options:
Smart transfer (updated panel files only):
Select to utilize the Smart Transfer feature, which
reduces the transfer time by only replacing those panel files that have been updated (relative to
the files already loaded in the panel). Any bitmaps, sound files and fonts that all already
• Baud Rate
38400
• Data Bits
8
• Parity
none
• Stop Bits
1
• Flow Control
none
• Phone Number
Enter the telephone number of the target Master.
These settings must match those of the Modem.
To refresh the Online Devices Tree, disconnect and reconnect via the commands in
the Transfer menu.
Содержание Modero NXD-1200VG
Страница 20: ...xviii TPDesign4 Touch Panel Design Software v2 10 or higher Table of Contents ...
Страница 130: ...List Box Buttons 110 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 160: ...Working With States 140 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 166: ...Working With Function Codes 146 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 174: ...Colors and Palettes 154 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 186: ...Animations and Tweening 166 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 208: ...Working With Templates 188 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 236: ...File Transfer Operations 216 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 248: ...Program Preferences 228 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 266: ...Appendix B G4 PanelBuilder 246 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 272: ...Appendix C TakeNote 252 TPDesign4 Touch Panel Design Software v2 10 or higher ...
Страница 273: ...Appendix C TakeNote 253 TPDesign4 Touch Panel Design Software v2 10 or higher ...