Epica DGX 32 SC Optical Boards
48
Epica DGX 32 Instruction Manual
Tip: For systems with special requirements – Before installing in the final location, place the
equipment close together, so the Control PC and the destination monitor can be seen
simultaneously if adjustments are necessary.
Safety Recommendations for Laser Products
Important: No user serviceable parts are included inside an AMX AutoPatch product; service should
only be done by qualified personnel.
Caution - Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Exercise caution when installing DGX products to avoid direct eye exposure to invisible laser radiation.
Follow the recommendations below whenever installing or working with DGX products.
Be sure to apply the power last, so that the fiber connector is not exposed when power is
applied.
Do not remove dust plugs from SC fiber connectors or the dust caps from the fiber cables until
establishing connections; avoid direct eye exposure.
Ensure all cables, including fiber cables, are correctly connected and/or terminated.
If you need to unplug a fiber cable on an input board, disconnect the power on the DGX TX
that is connected to the input.
If you need to unplug a fiber cable on an output board, disconnect the switch for that output
connector.
Attaching Cables
Instructions for attaching AMX AutoPatch cable management bars are on page 21. These bars are
recommended and provided with each DGX SC Optical Board.
Caution: Do not severely bend or kink the SC fiber cable. Irreversible damage can occur. Refer to
the physical limitations (bend radius) specified for the cable. The bend radius for AMX SC
terminated fiber cables is 2 inches (5 cm).
Check When Fastening Fiber Cables:
Ensure that no dust or debris is on the exposed ends of the fiber cable.
Ensure that the fiber cable connectors seat firmly into the board and module fiber connectors.
Normally an audible click is heard when a connector engages.
To connect SC fiber inputs and outputs:
1.
Recommended
–
Install the provided cable management bars (see page 21).
Caution: CLASS 3R INVISIBLE LASER RADIATION WHEN OPEN; AVOID DIRECT EYE
EXPOSURE.
2.
Clean the fiber cable connector
–
Follow the manufacturer’s recommendations.
3.
Remove the protective cap from the SC fiber connector.
Содержание Epica DGX 32
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 32 Distribution Matrix Release 3 19 2010 ...
Страница 6: ...Contents iv Epica DGX 32 Instruction Manual ...
Страница 12: ...Notices 6 Epica DGX 32 Instruction Manual ...
Страница 50: ...Installation and Setup 44 Epica DGX 32 Instruction Manual ...
Страница 56: ...Epica DGX 32 SC Optical Boards 50 Epica DGX 32 Instruction Manual ...
Страница 60: ...Epica DGX 32 DVI Boards 54 Epica DGX 32 Instruction Manual ...
Страница 98: ...NXB AP 1000 Interface Initial Setup by Network Admin 92 Epica DGX 32 Instruction Manual ...
Страница 102: ...NXB AP 1000 Interface Controlling the Epica DGX 32 96 Epica DGX 32 Instruction Manual ...
Страница 108: ...NXB AP 1000 Interface Additional Info for Network Admin 102 Epica DGX 32 Instruction Manual ...
Страница 114: ...Appendix A EDID Programmer 108 Epica DGX 32 Instruction Manual ...
Страница 126: ...Appendix B Managing Configuration Files 120 Epica DGX 32 Instruction Manual ...