Safety Recommendations for Laser Products
Important: No user serviceable parts are included inside an AMX AutoPatch product; service should
only be done by qualified personnel.
Caution - Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Exercise caution when installing DGX products to avoid direct eye exposure to invisible laser radiation.
Follow the recommendations below whenever installing or working with DGX products.
Be sure to apply the power last, so that the fiber connector is not exposed when power is
applied.
Do not remove dust plugs from SC fiber connectors or the dust caps from the fiber cables until
establishing connections; avoid direct eye exposure.
Ensure all cables, including fiber cables, are correctly connected and/or terminated.
If you need to unplug a fiber cable on an input board, disconnect the power on the DGX TX
that is connected to the input.
If you need to unplug a fiber cable on an output board, disconnect the switch for that output
connector.
Installation Procedure
A flow chart showing the installation sequence is in FIG. 7. The procedure, which follows, provides
general steps with references to detailed information found in later sections of the manual.
Caution: To prevent overheating and airflow restriction, avoid placing high heat producing
equipment directly above or below the enclosure. The system requires a minimum of one empty rack
unit above and below (three empty rack units are recommended). Verify that the openings on the top
and sides of the enclosure are not blocked and do not have restricted air flow.
Note: If desired, remove rubber feet from bottom of enclosure before rack installation.
To install and setup an Epica DGX 32 (requires a minimum of two people):
1.
Select a position in the rack for the Epica DGX 32 that is accessible and does not restrict airflow
(see Caution above).
2.
Position the enclosure in the rack. Screw in the rack ear screws on each side.
FIG. 7
Flow chart for installation procedure
FIG. 8
Rack mounting screws aligned with rack
Install
in rack
If multiple-
enclosure
system, link
enclosures
Optional -
Attach
controller
Attach 1st two input
& output cables.
If applicable, install
DGX Fiber modules
Apply power
to enclosure(s)
& then to
system devices
Execute
test switch
Attach all input
& output cables
Содержание Epica DGX 32
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 32 Distribution Matrix Release 3 19 2010 ...
Страница 6: ...Contents iv Epica DGX 32 Instruction Manual ...
Страница 12: ...Notices 6 Epica DGX 32 Instruction Manual ...
Страница 50: ...Installation and Setup 44 Epica DGX 32 Instruction Manual ...
Страница 56: ...Epica DGX 32 SC Optical Boards 50 Epica DGX 32 Instruction Manual ...
Страница 60: ...Epica DGX 32 DVI Boards 54 Epica DGX 32 Instruction Manual ...
Страница 98: ...NXB AP 1000 Interface Initial Setup by Network Admin 92 Epica DGX 32 Instruction Manual ...
Страница 102: ...NXB AP 1000 Interface Controlling the Epica DGX 32 96 Epica DGX 32 Instruction Manual ...
Страница 108: ...NXB AP 1000 Interface Additional Info for Network Admin 102 Epica DGX 32 Instruction Manual ...
Страница 114: ...Appendix A EDID Programmer 108 Epica DGX 32 Instruction Manual ...
Страница 126: ...Appendix B Managing Configuration Files 120 Epica DGX 32 Instruction Manual ...