Epica DGX 144 SC Fiber Boards
47
Epica DGX 144 Instruction Manual
System Setup with DGX Modules
DGX SC Fiber input and output boards are used in conjunction with AMX AutoPatch DGX SC Fiber
TX and RX modules. Compatible DGX SC Fiber modules are listed on page 46. For module installation
details and specifications, see the module’s
Quick Start Guide
or
Installation Manual
.
When the modules are installed, image adjustment and EDID scaling is automatically applied. For
almost every installation, the automatic features on the modules result in a satisfactory image on the
monitor. If the installation has special requirements and needs additional adjustment or if you need
product specifications for the modules, refer to the
Instruction Manual
–
DGX Transmitters & Receivers
on the
AMX AutoPatch CD
or at
www.amx.com
.
The distance from a DGX SC Fiber TX module to a DGX SC Fiber input board can be up to 3,000 feet
(914.4 m) and another 3,000 feet from a SC Fiber output board to a DGX SC Fiber RX module.
Note:
Along with the video signal, the DGX SC Fiber boards support embedded digital audio and
embedded analog stereo audio from the DGX SC Fiber modules. They also support the
transmission of unidirectional RS-232 (EIA-232) serial data with the data flow in the same direction
as the video signal.
Important:
The RS-232 connection on the modules requires management of the RS-232 data line in
relation to switching operations. In an upstream matrix switching scenario, we recommend that
RS-232 control commands (via the DGX RS-232 data connection) are not sent immediately prior or
subsequent to a matrix switching command. It is possible for the RS-232 data to be corrupted as the
video (or audio) signal is removed and then restored by the matrix switcher.
The system setup in FIG. 24 illustrates DGX SC Fiber boards used in conjunction with DGX modules.
The Transmitter modules (HD-15 and DVI) can be installed interchangeably. The Receiver modules
(HD-15 and DVI) are interchangeable as well, providing for an extremely flexible system. For example,
in the same system the source device can send a DVI signal and the destination device can receive an
RGBHV signal.
Tip:
For systems with special requirements
–
Before installing in the final location, place the
equipment close together, so the Control PC and the destination monitor can be seen
simultaneously if adjustments are necessary.
FIG. 24
DGX SC Fiber boards used in conjunction with DGX SC Fiber modules
Destination Device
SC fiber up to 3000 ft. (914 m)
Source Device
USB
DGX TX
DGX RX
Control PC for setup
–
only necessary for systems
with special requirements
SC fiber up to 3000 ft. (914 m)
Epica DGX 144 with
DGX SC Fiber boards
Содержание Epica DGX 144
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 144 Distribution Matrix REV C 1 25 2011 ...
Страница 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Страница 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Страница 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Страница 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Страница 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Страница 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Страница 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...