Overview and General Specifications
13
Epica DGX 144 Instruction Manual
Serial Number
The serial number is normally located on the rear of the enclosure on the left (FIG. 2 on page 10).
Before installation, we recommend recording the serial number for each enclosure in the system in an
easily accessible location.
General Specifications
For individual board information and specifications, see the specific board chapter in this manual.
Note:
Features and specifications described in this document are subject to change without notice.
Configuration Information and Control Options
The configuration file contains routing and control information for an AMX AutoPatch Routing System.
Each system is programmed (configured) at the factory according to customer specifications.
Configuration Information
As shipped from the factory, the Epica DGX 144 supports full Device Discovery. The factory
configuration contains two virtual matrices (VMs) for switching signals: VM 0 = all signals and VM 1 =
video signals (in systems like the Epica DGX 144, by default both VMs route the same signals).
Note:
When embedded audio is transmitted along with the video over the fiber, the audio switches
on the same VM as the video (the audio and video cannot be switched independently).
The custom configuration file is provided on the
AMX AutoPatch CD
that is shipped with each system.
XNConnect, the configuration software provided on the CD can be used to further customize the
configuration file (see page 69).
Unless you need to modify your system, you will
not
need to use any of the configuration software that
is included on the CD. If you do modify the configuration file, we recommend making a copy of it first.
Configuration file modifications include creating local presets, customizing input and output channel
names for control display (e.g., in APControl 3.0 or APWeb’s control interface), as well as adding or
managing hardware. Configuration file modifications are made with XNConnect, which graphically
displays the AMX AutoPatch system and its control configuration. Other configuration software for
specific hardware or for adjusting signal quality is also available on the
AMX AutoPatch CD
. For details,
see the individual program’s Help file.
Specifications
Parameter
Value
Approvals
CE, UL, cUL, RoHS, FCC Class A
AC Power per Supply
100 VAC to 240 VAC single phase (50 Hz to 60 Hz)
Power Consumption (max.)
1563 Watts
Power Consumption (typical)
850 Watts, fully loaded enclosure
Thermal Dissipation (max.)
5333 BTU/hr.
Thermal Dissipation (typical)
2900 BTU/hr., fully loaded enclosure
Operational Temperature (continuous)
32° F to 110° F (0°C to 43° C)
Humidity
0 to 90% non-condensing
Dimensions
20.08 in. (51 cm) depth; 21.08 in. (53.54 cm) with extractors
19 in. (48.26 cm) width with rack mounting ears
17.6 in. (44.7 cm) width behind rack mounting ears
28 in. (71.1 cm) height (16 RU)
Weight
Approximately 160 lb. (72.6 kg) per loaded enclosure
Shipping Weight
Approximately 205 lb. (93 kg) per loaded enclosure
Содержание Epica DGX 144
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 144 Distribution Matrix REV C 1 25 2011 ...
Страница 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Страница 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Страница 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Страница 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Страница 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Страница 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Страница 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...