Installation and Setup
17
Epica DGX 144 Instruction Manual
Installation and Setup
UL Site Requirements
Warning:
Per UL requirements
–
“This product must be installed within a restricted access location
where access is through the use of a tool, lock and key, or other means of security, and is controlled
by the authority responsible for the location. This product must be installed and maintained only by
qualified technicians.”
The precautions in the Warning above are required due to accessible hazardous energy levels from the
power supplies (greater than 240 W of available power). The energy levels are considered accessible
because the input and output boards are removable by hand.
UL Safety Certifications, Notices, and Recommendations for Laser Products
Per UL requirements, note the following:
The DGX Fiber boards comply with IEC Standard: IEC 60825-1, 2001.
The boards also comply with 21 CFR 1040.10 and 1040.11 except for deviations pursuant
to Laser Notice No. 50, dated June 24, 2007.
The DGX TX Fiber boards are CLASS 1 LASER PRODUCTS.
The maximum output power of the laser radiation is 4.08 mW.
Since the class of radiation emitted from the fiber port can be Class 3R when the fiber cable or dust plug
is removed, a yellow and black label with the following caution is located on the rear of the enclosure to
the right of the power supplies:
Important:
No user serviceable parts are inside an AMX AutoPatch product; service should only be
done by qualified personnel.
Caution:
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Exercise caution when installing DGX products to avoid direct eye exposure to invisible laser radiation.
Follow the recommendations below whenever installing or working with DGX products.
Be sure to apply the power only after all fiber connections are made and no fiber ends are
exposed.
Do
not
remove dust plugs from SC fiber connectors or the dust caps from the fiber cables until
establishing connections;
avoid direct eye exposure
.
Make sure all cables, including fiber cables, are correctly connected and/or terminated.
Before you unplug a fiber cable on an input board, disconnect the power on the DGX TX that is
connected to the input.
Before you unplug a fiber cable on an output board, disconnect the switch for that output
connector.
FIG. 6
Caution label for Class 3R laser products
Содержание Epica DGX 144
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 144 Distribution Matrix REV C 1 25 2011 ...
Страница 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Страница 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Страница 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Страница 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Страница 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Страница 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Страница 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...