Appendix E – Board Replacement
100
Epica DGX 114 Instruction Manual
9.
Enter
~scri4v3!
to verify that the system recognizes the board.
Check to be sure the new board is included in the list (FIG. 46). If not, reseat the board and enter the
command again.
10. Optional for systems with SC Fiber boards
– Power down the enclosure.
11.
If applicable – Attach the cable management bar using two screws at the top and two screws at the
bottom (do
not
over tighten screws).
Note:
If using a cable management bar, tie the cable to the cable management bar far enough below
the connector to allow for the manufacturer’s recommended bend radius. The bend radius for
AMX SC terminated fiber cables is 2 inches (5 cm).
12.
Attach the cables to the board’s connectors* and reconnect any other cables that were disconnected
in Step 2 (if applicable – tie cables to cable management bars).
If the system is not powered down:
For connecting a DGX SC Fiber input board
– Avoid direct eye exposure as you
(a) remove the dust plugs from the SC fiber connectors, (b) remove the dust caps from the
fiber cables, (c) establish the connections, and (d) apply power to the DGX TX Transmitter
modules that are connected to the inputs.
For connecting a DGX SC Fiber output board
– Avoid direct eye exposure as you
(a) remove the dust plugs from the SC fiber connectors, (b) remove the dust caps from the
fiber cables, and (c) establish the connections.
13. If the enclosure was powered down
– Reapply power.
14.
Important – Update the system’s configuration file if necessary (to determine if this is necessary, see
the next page).
15.
Execute a test switch that includes a signal routed on the new board to make sure the system is
working correctly. (Repeat for any additional new boards.)
*If you need cabling information, see the specific board chapter in this manual.
FIG. 46
Splash screen showing boards in the system (example with 6 input boards)
~scri4v3!
[4:Hardware Boards] detected
[switching drivers] count = 4
(Scroll past switching drivers information to view board information.)
[input boards] count = 6
[bid 1] C020
[bid 2] C020
[bid 3] C020
[bid 4] C020
[bid 5] C020
[bid 6] C020
Number of boards listed must
match the actual number of
boards in the enclosure
bid = board ID
Содержание Epica DGX 144
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 144 Distribution Matrix REV C 1 25 2011 ...
Страница 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Страница 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Страница 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Страница 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Страница 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Страница 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Страница 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...