Appendix E – Board Replacement
98
Epica DGX 114 Instruction Manual
Safety Recommendations for Laser Products
Important:
No user serviceable parts are inside an AMX AutoPatch product; service should
only be done by qualified personnel.
C
aution:
Use of controls or adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
Exercise caution when installing DGX 144 SC Fiber boards to avoid direct eye exposure to invisible
laser radiation. Follow the recommendations below whenever installing or working with DGX products.
Be sure to apply the power only after all fiber connections are made and no fiber ends are
exposed.
Do
not
remove dust plugs from SC fiber connectors or the dust caps from the fiber cables until
establishing connections;
avoid direct eye exposure
.
Make sure all cables, including fiber cables, are correctly connected and/or terminated.
Before you unplug a fiber cable on an input board, disconnect the power on the DGX TX that
is connected to the input.
Before you unplug a fiber cable on an output board, disconnect the switch for that output
connector.
Replacing or Adding a Board
Important:
When replacing a board, be sure to install the new board in the same slot that held the
original board to make sure the switching commands are correct after you reconnect the source or
destination devices.
Important:
Cable management bars are not to be used as handles to remove or install boards.
In the following procedure, read each step entirely. The steps include helpful tips to avoid damage to the
enclosure’s internal cables and connectors.
To remove and replace an Epica DGX 144 board:
1. Optional for systems with SC Fiber boards
– Power down the enclosure (see the “Caution” at the
2.
If applicable – Label and disconnect all cables on the board being replaced. If cables from adjoining
boards obstruct access, label and disconnect them as necessary.
If the system is not powered down:
For disconnecting a DGX SC Fiber input board
– Before disconnecting the fiber cables,
disconnect the power on the DGX TX Transmitter modules that are connected to the board’s
input connectors.
For disconnecting a DGX SC Fiber output board
– Before disconnecting the fiber cables,
disconnect the switches for the board’s output connectors.
3.
If applicable – Remove the cable management bar (two screws at the top and two screws at the
bottom).
4.
Blank board plate – Push out on the board plate’s extractor handles as far as they will go (about a
45° angle), and then pull the blank plate straight out of the board slot opening.
Or
Current board – Push out on the board’s extractor handles as far as they will go (about a 45° angle).
Содержание Epica DGX 144
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 144 Distribution Matrix REV C 1 25 2011 ...
Страница 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Страница 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Страница 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Страница 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Страница 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Страница 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Страница 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...