Appendix C – APDiagnostics
89
Epica DGX 144 Instruction Manual
When processing a set of archived files in Emulation mode for analysis, you can control how fast or slow
the files are processed by adjusting the “Emulation Mode Packet Interval” setting on the General tab of
the Application Preferences dialog box. If you are viewing graphs while the data is being processed,
specifying a larger interval value will allow the program to be more responsive as the Plot Views can be
processor intensive in the face of fast playbacks.
Tip:
It is important to note that APDiagnostics keeps a cache of historical data points in memory for
status of all components that it monitors. These data points can then be displayed in the Plot Views
for trend analysis. You can control the amount of system memory APDiagnostics will use for this
historical data by setting the “Cached Probe History” value on the General tab. (Max. Cached Probe
History = 168 hours. For default values, see the dialog box.) Large history sets may impede
performance of the application, so set this value in accordance with the resources available on the
target PC.
Logging Tab
To set the preference for Start .acp Logging At Startup:
1.
Click the Enabled check box.
2.
Click OK.
To change settings:
1.
Edit in place (for default values, see the dialog box):
Log File Maximum Size*
Diagnostic Log Directory Max Size
ACP Log Directory Max Size
Activity Log Viewer Directory Max Size
2.
Click OK.
* Log files are automatically zipped when the maximum size specified in this field is reached. This size
value applies to all three log file types.
Tip:
The amount of disk space allocated for archived files can be controlled by specifying the
amount of disk space to allocate for each of the three file types that are generated and archived
while APDiagnostics is running in Acquisition mode. You can also specify how big the active Log file
should get before the file is archived and a new one is started. These parameters are specified on
the Logging tab.
Click to enable
Edit in place
Содержание Epica DGX 144
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 144 Distribution Matrix REV C 1 25 2011 ...
Страница 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Страница 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Страница 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Страница 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Страница 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Страница 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Страница 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...