Installation and Setup
28
Epica DGX 144 Instruction Manual
Linking More Than Two Enclosures
Linking an Epica DGX 144 enclosure to multiple other types of enclosures (other than linking in a daisy
chain off an enclosure with a 10Base-2 / BNC connector) requires a Multi-Port Switch and RJ-45
straight-through patch cables. Depending on the other types of enclosures, a Media converter(s) and
RG-58 coax cable(s) may also be required. FIG. 12 below shows an Epica DGX 144 enclosure linked to
an Optima and to a Modula using a 5-Port Switch and a Media Converter.
Important:
If the system has an RJ-45 connector labeled TCP/IP, do not use it for linking
enclosures. Do not use an RJ-45 enclosure linking connector for a TCP/IP connection.
Cable Length Requirements
Note:
If you have questions regarding cabling or network related issues in conjunction with using a
Multi-Port Switch (or hub) for linking enclosures, contact your network administrator.
When attaching multiple enclosures to a Multi-Port Switch, one or more can be connected directly to
the Multi-Port Switch (see steps below) and/or one or more can use a Media Converter to connect to
the Multi-Port Switch (see steps on page 29). In a system with multiple 10Base-2 enclosures, only one
needs to be attached to the Multi-Port Switch with a Media Converter. The rest can be daisy-chained.
To link an Epica DGX 144 enclosure to a Multi-Port Switch:
1.
Insert one end of the RJ-45 straight-through patch cable into the Enc Link (RJ-45) Ethernet port on
the Epica DGX 144 enclosure.
2.
Insert the other end of the RJ-45 straight-through patch cable into the Multi-Port Switch.
3.
Repeat Steps 1 and 2 for enclosures with 10Base-T ports.* For 10Base-2 ports, go to page 29.
* Applies when linking an Optima, Optima SD, Precis SD, or Epica DGX 16/32 to a Multi-Port Switch
.
Important:
Attach 50-ohm termination connectors to the open ends of the T-connectors on the
Media Converter and on the last enclosure on the cable run.
Network Segment
Cable Type
Maximum Distance
Epica DGX 144 to Multi-Port Switch
RJ-45 straight-through patch
100 ft. (30.5 m)
Multi-Port Switch directly to another type enclosure RJ-45 straight-through patch
100 ft. (30.5 m)
Multi-Port Switch to Media Converter
RJ-45 straight-through patch
100 ft. (30.5 m)
Media Converter to last enclosure in daisy chain
RG-58 coax
10 ft. (3.05 m) total
FIG. 12
Epica DGX 144 enclosure linked to an Optima and a Modula
The total length of all cables between the
Media Converter and the last enclosure in a
daisy chain cannot exceed 10 ft. (3.05 m).
Straight-through patch cable - max. 100 ft. (30.5 m) each cable
RG-58 coax cable
Max. 10 ft. (3.05 m)
Media Converter
5-Port Switch
50-ohm termination connectors
Link
Link Modula
(See steps above)
(See steps
Link Optima
(See steps above)
on next page)
Epica DGX 144
Содержание Epica DGX 144
Страница 1: ...Instruction Manual AutoPatch Matrix Switchers Epica DGX 144 Distribution Matrix REV C 1 25 2011 ...
Страница 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Страница 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Страница 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Страница 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Страница 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Страница 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Страница 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...