Using the DXP-HT Project Wizard
40
DXP-HT v1.3 - Programmer’s Guide
The identifier entered into the
Preset Name
text box is the name that will be displayed on
the touch panel. No duplicates allowed (8 characters maximum).
The
Address
field correspond to either the lighting controller address and the preset
number (as with AMX Radia), or the address of the keypad and the keypad button that
will be emulated (as with the LiteTouch controller).
For the AMX ALD-D48, the address is the 7-digit ID number of the ALD-D48 Device
Server.
For the AMX Radia the address is the AXlink address of the Radia MC.
The only valid keypad address characters are 0-9, A-F, and : (colon). For reference, here
are the formats for the various supported lighting systems:
Click the
Apply
button after editing a preset to apply the changes.
The
Button #
refers to the button number or scene number the DXP-HT system is to
emulate when communicating to the lighting system.
For
AMX Radia
, the button # is the scene number to be recalled when this scene is
selected on the touch panel.
For
Clipsal C-Bus
and
Dynalite
systems (used primarily outside the U.S.), the button #
consists of the button number plus the fade rate, separated by a semi colon. For example:
(C-Bus):
K:P:[A4:E1]:75:8
indicates network $E1, group address $A4, go to 75%
at 8-second fade rate.
Lighting Controller
Address Format
DXP-HT Example
• AMX ALD-D48
The Address value is fixed at a value of one
and is disabled. This value corresponds to the
Device ID of the keypad.
1 (read-only)
• AMX Radia
AXlink Device ID (1-255)The Address is the
AXlink device ID of the Radia MC.
96
• Clipsal C-Bus
Group Address:Network Address (using a hex
value and a local network address)
A1:D4
• DynaLite
DynaLite area (positive integer)
18
• Lehigh DX2
Lehigh area (1 - 16)
1
• Lutron GRAFIK Eye
Master (positive integer)
17
• Lutron Homeworks
Interactive
Processor:Link:Keypad (positive integers)
1:4:9
• Lutron RadioRA
Keypad Address (positive integer)
Note: keypad address 12 is reserved as the
RS-232 RadioRA interface. This interface is a
virtual keypad, and does not contain any but-
tons.
12
• LiteTouch 5000LC
Keypad Address (3 nibble hex value
A3E
• Tridonic DALI
Tridonic group address (0 -15)
0
• Vantage Qlink
Master:Keypad (positive integers)
1:5
For the AMX ALD-D48, the Address field value is fixed at a value of one (1) and is
read-only. This value corresponds to the Device ID of the keypad.