![background image](http://html1.mh-extra.com/html/ametek/sorensen-sg-series/sorensen-sg-series_programming-manual_2931312097.webp)
SG Series Programming
SCPI Command Operation
M550129-03 Rev L
6-31
Command
Description
SCPI
:SAVELAST <0|1>
Sets the SAVELAST condition
“0” disables SAVELAST feature
“1” enables SAVELAST feature
N
:SAVELAST?
Returns the status of the Save Last condition
N
:OUTPut
Calibrate Output subsystem
N
:CURRent
Calibrate Output Current subsystem
N
:CALCulate
Calculates the value of the gain and offset for output
current.
N
:DAC <NR1>
Sets the output of the output current D/A converter.
N
:FIVEPOINT
<1|2|3|4|5>
(Ethernet only) Sets output current value for each
calibration point (1-5)
N
:FIVEPOINT?
(Ethernet only) Returns the entered values for 5-
point calibration.
N
:GAIN <NRf>
Sets the value of the gain for the output current.
N
:GAIN?
Returns the value of the gain for the output current.
N
:OFFSet <NRf>
Sets the value of the offset for the output current.
N
:OFFSet?
Returns the value of the offset for the output current.
N
:POINt <1|2> <NRf>
Sets the current output calibration point
(1 or 2). The actual output current is measured with
an external meter.
N
:VOLTage
Calibrate Output Voltage subsystem
N
:CALCulate
Calculates the value of the gain and offset for output
voltage.
N
:DAC <NR1>
Sets the output of the output voltage D/A converter.
N
:FIVEPOINT
<1|2|3|4|5>
(Ethernet only) Sets output voltage value for each
calibration point (1-5)
N
:FIVEPOINT?
(Ethernet only) Returns the entered values for 5-
point calibration.
N
:GAIN <NRf>
Sets the value of the gain for the output voltage.
N
:GAIN?
Returns the value of the gain for the output voltage.
N
:OFFSet <NRf>
Sets the value of the offset for the output voltage.
N
:OFFSet?
Returns the value of the offset for the output voltage.
N
:POINt <1|2> <NRf>
Sets the voltage output calibration point
(1 or 2). The actual output voltage is measured with
an external meter.
N
:PROTection
Calibrate Output Voltage Protection subsystem
N
:CALCulate
Calculates the value of the gain and offset for output
overvoltage protection. This takes more than 30
seconds to complete. Use
*ESE 1
and a serial poll
to detect the completed operation.
N
:DAC <NR1>
Sets the output of the output overvoltage protection
D/A converter.
N
:GAIN <NRf>
Sets the value of the gain for the output overvoltage
protection.
N
:GAIN?
Returns the value of the gain for the output
overvoltage protection.
N
:OFFSet <NRf>
Sets the value of the offset for the output overvoltage
protection.
N
:OFFSet?
Returns the value of the offset for the output
overvoltage protection.
N
:UNLock <string>
Sets the non-volatile memory available to store
calibration constants. The access string is “6867”.
:STORe
Stores the calibration constants in non-volatile
memory.
N
Содержание Sorensen SG Series
Страница 2: ......
Страница 4: ...Contents SG Series Programming viii M550129 03 Rev L This page intentionally left blank...
Страница 6: ...Contents SG Series Programming x M550129 03 Rev L This page intentionally left blank...
Страница 8: ...Contents SG Series Programming xii M550129 03 Rev L This page intentionally left blank...
Страница 14: ...Contents SG Series Programming xviii M550129 03 Rev L This page intentionally left blank...
Страница 16: ...Overview SG Series Programming 1 2 M550129 03 Rev L This page intentionally left blank...
Страница 126: ...SCPI Command Operation SG Series Programming 6 60 M550129 03 Rev L This page intentionally left blank...
Страница 143: ...M550129 03 Rev L 8 1 SECTION 8 SCPI STATUS IMPLEMENTATION...
Страница 144: ...SCPI Status Implementation SG Series Programming 8 2 M550129 03 Rev L This page intentionally left blank...
Страница 146: ...This page intentionally left blank...