SG Series Programming
Ethernet Configuration and Remote Programming
M550129-03 Rev L
5-19
update (or make all desired changes before
clicking
Apply
). This field has no factory setting.
Listening Port
– input a port number for the
embedded Web server, ranging in value from
1025
– 65535. Click
Apply
to update (or make all
desired changes before clicking
Apply
). The
factory default port number is 9221.
To automate:
(To return to the default setting): Click the radio
button next to
Obtain an IP Address
Automatically
for dynamic address acquisition
from the DHCP server.
Auto IP
Enabled
: allows the power supply to
assign itself an IP address in the range from
169.254.0.1 to 169.254.255.254 with a subnet
mask of 255.255.0.0. If it is enabled, when there
is no DHCP server available, the power supply
will assign itself an IP address. However, please
keep in mind that when you select
Obtain an IP
Address Automatically
and
you check
Auto IP
Enabled
in
TCP/IP Primary Configuration
, the
system will not try the Secondary Configuration.
To enable:
Click in the box to check; click again to uncheck
so that it is no longer enabled.
Example TCP/IP Configurations:
Primary: Use a Static IP Address
Secondary: Obtain an IP Address Automatically
(DHCP)
At power-up the power supply will assign itself the configured static IP
address. If no other device is using the IP address, the power supply
continues with that static IP address. If some other device is using that
address, the power supply will move to Secondary and attempt to
acquire an IP address from a DHCP server repeatedly until it gets an
address.
Primary: Use a Static IP Address
Secondary:
Obtain an IP Address Automatically
(DHCP) and
AutoIP
Enabled
At power-up the power supply will assign itself the static IP address. If
no other device is using the IP address, the power supply continues with
that static IP address. If some other device is using that address, the
power supply will move to secondary and attempt to acquire an IP
address from a DHCP server. If it cannot find a DHCP server to assign
an address, it will assign itself a link-local address. If no other device is
using that link-local address it will use it for 5 minutes minimum. At that
time, if it is already in communication with some other device, it will hold
onto that link-local address until the communication is finished and then
retry DHCP. Then, if DHCP is not available, the power supply will revert
to the last successful link-local address for another 5 minutes minimum.
Содержание Sorensen SG Series
Страница 2: ......
Страница 4: ...Contents SG Series Programming viii M550129 03 Rev L This page intentionally left blank...
Страница 6: ...Contents SG Series Programming x M550129 03 Rev L This page intentionally left blank...
Страница 8: ...Contents SG Series Programming xii M550129 03 Rev L This page intentionally left blank...
Страница 14: ...Contents SG Series Programming xviii M550129 03 Rev L This page intentionally left blank...
Страница 16: ...Overview SG Series Programming 1 2 M550129 03 Rev L This page intentionally left blank...
Страница 126: ...SCPI Command Operation SG Series Programming 6 60 M550129 03 Rev L This page intentionally left blank...
Страница 143: ...M550129 03 Rev L 8 1 SECTION 8 SCPI STATUS IMPLEMENTATION...
Страница 144: ...SCPI Status Implementation SG Series Programming 8 2 M550129 03 Rev L This page intentionally left blank...
Страница 146: ...This page intentionally left blank...