Structure and function
72
EDX 9000-TC BAH0048-6 09.2019
5.5.3
Seed shutter
The seed flows from the seed hopper to the fluid
bed (Fig. 61/1) directly in front of the singling
drum.
The fluid bed may not be completely filled with
seed. Otherwise, a fluidised bed cannot be
created when air is supplied later on.
If too much seed enters the fluid bed, reduce the
feed quantity by adjusting the seed shutter (Fig.
61/2).
Fig. 61
The sight glass should be half full with seed
when the implement is at rest.
The adjustment of the seed shutter depends on
the working speed and the seed.
Fig. 62
5.5.4
Air baffle
Air flowing through the fluid bed sets the seed
grains in front of the singling drum in motion
The air quantity is correctly metered when the
seed grains
move loosely at the viewing window
(without jumping).
are not thrown across the singling drum.
Fig. 63