Adjusting the fertiliser placement depth
The adjustable coulter pressure applies a load of up to 200 kg on the
fertiliser coulter. The required fertiliser placement depth is only
achieved when the coulter pressure is correctly set.
1. Unscrew the lock nut (Fig. 200/1).
2. Turn the valve screw (Fig. 200/2) to adjust
the fertiliser coulter pressure.
Read off the fertiliser coulter pressure at the
pressure gauge (Fig. 200/3).
3. Tighten the lock nut.
Fig. 200
In the tractor track, the placement depth of individual fertiliser coulters
can be separately adjusted in addition to the hydraulic adjustment.
1. Loosen the fastening nut (Fig. 201/1).
2. Loosen the adjustment screw (Fig. 201/2)
and remove.
Fig. 201
DANGER
Do not stand in the swivelling area
of the fertiliser coulters!
3. Swivel the fertiliser coulter to the desired
position (Fig. 201/3).
4. Insert the adjustment screw (Fig. 201/2)
and tighten.
5. Tighten the fastening nut (Fig. 201/1).
Always check the placement depth of the fertiliser:
before starting work
following every adjustment of the fertiliser coulter pressure
if the forward speed changes during operation
if the soil conditions change.
Drive the implement across the field for a distance of roughly 100 m at
the intended working speed and check the placement depth, adjust if
necessary.
Содержание EDX 9000-TC
Страница 27: ...General Safety Instructions EDX 9000 TC BAH0048 6 09 2019 27 Fig 3 Fig 4...
Страница 212: ...Cleaning maintenance and repairs 212 EDX 9000 TC BAH0048 6 09 2019 Fig 304 Fig 305 Fig 306 Fig 307 Fig 308 Fig 309...
Страница 243: ...Hydraulic diagram EDX 9000 TC BAH0048 6 09 2019 243 Fig 346...
Страница 244: ...Hydraulic diagram 244 EDX 9000 TC BAH0048 6 09 2019...
Страница 245: ...Notes EDX 9000 TC BAH0048 6 09 2019 245 14 Notes Space for your notes...