8.7
Adjusting fan speed
The fan speed alters until the hydraulic fluid has reached its
working temperature.
On initial operation correct the fan speed up to attainment of the
working temperature.
If the fan is put back into operation after a long stoppage period, the
preset fan speed is not attained until the hydraulic fluid has heated
up to working temperature.
DANGER
Do not exceed the maximum fan speed of 4000 rpm.
The maximum approved system
pressure is 210 bar, which can be read
on the pressure gauge (Fig. 212/1)
beside the fan hydraulic motor.
Fig. 212
The seed hopper cover (Fig. 213/1)
must be closed before switching
on the fan (Fig. 213/2)
must always be kept closed when
the fan is running.
Fig. 213