![Amazone EDX 9000-TC Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/amazone/edx-9000-tc/edx-9000-tc_operating-manual_2919753146.webp)
Settings
146
EDX 9000-TC BAH0048-6 09.2019
8.2.4
Setting the fertilising rate using a calibration test
1. Fill the fertiliser hopper with at least 200 kg
of fertiliser (see section "Filling the hopper",
Seite 177).
2. Unfold the implement into the working
position (see section "Unfolding the
implement sections", page 171).
Fig. 193
CAUTION
Switch off the tractor PTO shaft, apply
the tractor parking brake, switch off
the tractor engine and remove the
ignition key.
3. Insert a calibration trough into the holder
under each metering unit (Fig. 193/1).
4. Open all of the injector sluice flaps (Fig.
194/1).
The opening at the bottom of the injector sluice is
closed when
the lever (Fig. 195/1) of the left injector
sluice points to the left in the direction of
travel
the lever of the right injector sluice points to
the right in the direction of travel.
Note:
The left injector sluice is shown.
Lever position (Fig. 195/1):
closed
Lever position (Fig. 195/2):
open.
A slider element closes the opening. The slider
element is actuated by a lever (Fig. 195/1). Make
sure that the lever engages when opening and
closing the sliding element.
Fig. 194
Fig. 195
Содержание EDX 9000-TC
Страница 27: ...General Safety Instructions EDX 9000 TC BAH0048 6 09 2019 27 Fig 3 Fig 4...
Страница 212: ...Cleaning maintenance and repairs 212 EDX 9000 TC BAH0048 6 09 2019 Fig 304 Fig 305 Fig 306 Fig 307 Fig 308 Fig 309...
Страница 243: ...Hydraulic diagram EDX 9000 TC BAH0048 6 09 2019 243 Fig 346...
Страница 244: ...Hydraulic diagram 244 EDX 9000 TC BAH0048 6 09 2019...
Страница 245: ...Notes EDX 9000 TC BAH0048 6 09 2019 245 14 Notes Space for your notes...