10. Setting of Measurement Mode and Schedule
10-16
(9) Tangential Mode “Force Measure Mode : TANG(3)”
This is the mode for measuring force. The welding starts when the set weld force value
is reached, and the after-welding force can be measured and judged.
The welding can be started with a given weld force.
a. Setting of measurement mode
1
Press FUN, 0 and ENT keys in this order to select “0=Setup”.
2
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis).
3
Set No.3 “Disp Measure Mode” (measurement mode of displacement sensor) to
an item other than “SYNC(0)” (synchro mode); “SQNC(1)” (sequence mode),
“SH1(2)”, “SH2(3)”, or “SH3(4)” (sample hold mode).
4
Set the rated capacity of the connected load cell in No.4 “L.C. Rated Capacity”.
The rated capacity of the load cell is shown on the certificate of the load cell.
5
Select the force unit from “N(0)”, “kgf(1)”, and “lbf(2)” in No.5 “Loadcell Unit”.
6
Set the rated output of the connected load cell in No.6 “L.C. Rated Output”. The
rated output of the load cell is shown on the certificate of the load cell.
7
When there is a limit switch for force check, set No.7 “LS Input Validity” (use of
force-detecting signal input) to “Valid(0)”. When not using the force-detecting
signal (LS), set it to “Invalid(1)”.
8
Set No.8 “Force Measure Mode” (measurement mode of load cell) to “TANG(3)”
(tangential mode).
9
Set the measurement point for “After Weld Force” in No.24 “Tang Measure
Point” to “Weld(0)” or “Hold(1)”.
b. Setting of measurement schedule
1
Press MONI key to display the normal screen.
2
Press SCH key to select “SCH Axis”.
Welding start with
the set weld force !
Welding
[Tang Measure Point]
Select either measurement point:
Force start with
ST-Force signal
Time
Force
Force
measurement
Weld start output
force point
Hold time
Weld time