MU-100A
6. Interface
6-4
d. OUTPUT2 connector: KF22X-B37S-NJM(KYCON)
* For SENSOR3 and 4 (option)
* Use the shielded cable for the output cable and connect the shielded part to the ground.
No
Symbol Contents
1 READY2
Device normal signal. Turned OFF while the setting screen is displayed.
2 GOOD-DISP2
The GOOD signal of displacement sensor when the Disp Measure Mode for
SENSOR3 and 4 is set to SYNC, SQNC, or SH1,2,3. When it is set to SYNC,
this is the GOOD signal common to the displacement sensor and the load
cell.
3 GOOD-FORCE2
The GOOD signal of load cell when the Force Measure Mode for SENSOR4
is set to SQNC, SH1/2, or TANG. Do not use when the Disp Measure Mode is
set to SYNC.
4 NG2
Output when the measured value for SENSOR3 and 4 is outside the
upper/lower limit.
5 NG-UP2
Output when the measured value of the displacement sensor for SENSOR3
exceeds the upper limit.
6 NG-LO2
Output when the measured value of the displacement sensor for SENSOR3
falls below the lower limit.
7 NG-BEFORE2
Output when the before-welding workpiece thickness for SENSOR3 is NG.
8 NG-DISP2
Output when the displacement for SENSOR3 is NG.
9 NG-AFTER2
Output when the after-welding workpiece thickness for SENSOR3 is NG.
10 NG-FORCEUP2
Output when the measured value of the load cell for SENSOR4 exceeds the
upper limit.
11 NG-FORCELO2
Output when the measured value of the load cell for SENSOR4 falls below
the lower limit.
12 OUTPUT27
Spare
output
signal.
13 WELD
START2
The start signal for welding power supply for SENSOR3 and 4. Output for the
time set in Weld-Time.
14 FINISH2
Output when the sequence operation for SENSOR3 and 4 ends.
15 LEV-DISP21
16 LEV-DISP22
17 LEV-DISP23
Output when the present value of the displacement sensor for SENSOR3
passes the setting.
18 LEV-FORCE21
19 LEV-FORCE22
20 LEV-FORCE23
Output when the present value of the load cell for SENSOR4 passes the
setting.
21 OUTPUT21
22 OUTPUT22
23 OUTPUT23
24 OUTPUT24
25 OUTPUT25
26 OUTPUT26
Spare output signals.
27 SVCOM2
Common for the solenoid valve control signal for SENSOR3 and 4.
28 SV21
The solenoid valve control signal for SENSOR3 and 4.
29 SV22
30 SV23
Spare solenoid valve control signal.
31 V-SIG21
Converts the present value of the displacement sensor for SENSOR3 to
voltage to output it. *1
32 V-SIG22
Converts the present value of the load cell for SENSOR4 to voltage to output
it. *2
33 V-SIGCOM2
Common for voltage output for SENSOR3 and 4.
34 OUTCOM
35 OUTCOM
36 OUTCOM
37 OUTCOM
Common for output signals for SENSOR3 and 4.