MU-100A
8. Function Setting
8-2
(2) Setting Common Items (0=Setup)
Sets common items.
a. Setup menu
When 0=Setup is selected, the LCD display becomes as shown below.
Select the axis to set and press ENT key to display the setup setting screen.
Move the cursor to the item number of parameter to set with
▼
,
▲
or numeric
key.
Next, move the cursor to the setting item to change with
▼
key, change it with
▼
,
▲
or numeric key, establish it with ENT key.
b. Parameter item
* Highlighted items are initial values.
No
Item
Selections,
Setting range
Description
1
Using sensor
pattern
Sen_1/Load_1(0)
Sen_2/Load_2(1)
Displays the usage state of the main unit.
Sen_1/Load_1(0): 1-axis type
1 load cell and 1 displacement sensor can be
connected.
Sen_2/Load_2(1): 2-axis type
2 load cells and 2 displacement sensors can be
connected.
(Fixed before shipment. Cannot be changed.)
2
Sensor Type
Incremental(1)
Displays the connectable displacement sensor type.
Incremental(1): Incremental type
Ex.) Mitutoyo, Ono Sokki, Keyence, etc.
(Fixed before shipment. Cannot be changed.)