MU-100A
6. Interface
6-5
*1 Output value of V-SIG11 and V-SIG21
According to the range set in “Disp Voltage Range” (see
8. Function Setting
), the present value of the
displacement sensor is converted to ±10 V to be output (see table below). When the present value of
displacement sensor exceeds the set range, the value is saturated with ±10 V.
Output voltage
Disp Voltage
Range setting
+10 V
+5 V
0 V
-5 V
-10 V
0.255
+0.255 mm
+0.127 mm
0 mm
-0.127 mm
-0.255 mm
0.511
+0.511 mm
+0.255 mm
0 mm
-0.255 mm
-0.511 mm
1.023
+1.023 mm
+0.511 mm
0 mm
-0.511 mm
-1.023 mm
2.047
+2.047 mm
+1.023 mm
0 mm
-1.023 mm
-2.047 mm
4.095
+4.095 mm
+2.047 mm
0 mm
-2.047 mm
-4.095 mm
8.191
+8.191 mm
+4.095 mm
0 mm
-4.095 mm
-8.191 mm
16.383
+16.383 mm
+8.191 mm
0 mm
-8.191 mm
-16.383 mm
32.767
+32.767 mm
+16.38 mm
0 mm
-16.38 mm
-32.767 mm
65.535
+65.535 mm
+32.76 mm
0 mm
-32.76 mm
-65.535 mm
When monitoring the waveform with an oscilloscope, use an oscilloscope whose channels are
insulated.
*2 Output value of V-SIG12 and V-SIG22
Based on the rated capacity set in “L.C. Rated Capacity” (see
8. Function Setting
), the load variation
is converted to 0 to +10 V to be output (see table below). When the present value of the load cell
exceeds the set rated capacity, the value is saturated with 10 V.
Output voltage
Load cell
0 V
+2 V
+4 V
+6 V
+8 V
+10 V
L.C. Rated
Capacity
LS-20NC
0 N
4 N
8 N
12 N
16 N
20 N
20 N
LS-50NC
0 N
10 N
20 N
30 N
40 N
50 N
50 N
LS-200NC
0 N
40 N
80 N
120 N
160 N
200 N
200 N
LS-500NC
0 N
100 N
200 N
300 N
400 N
500 N
500 N
LS-2000NC
0 N
400 N
800 N
1200 N
1600 N
2000 N
2000 N
LS-5000NC
0 N
1000 N
2000 N
3000 N
4000 N
5000 N
5000 N
LCN-A-10KN
0 N
2000 N
4000 N
6000 N
8000 N
10000 N
10000 N
When monitoring the waveform with an oscilloscope, use an oscilloscope whose channels are
insulated.