10. Setting of Measurement Mode and Schedule
10-14
(8) Sample Hold 2 Mode “Force Measure Mode :
SH2(2)”
This is the mode for measuring force. The welding starts when the set weld force
value is reached, and the maximum force during welding can be measured and
judged.
The welding can be started with a given weld force.
a. Setting of measurement mode
1
Press FUN, 0 and ENT keys in this order to select “0=Setup”.
2
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis).
3
Set No.3 “Disp Measure Mode” (measurement mode of displacement sensor) to
an item other than “SYNC(0)” (synchro mode); “SQNC(1)” (sequence mode),
“SH1(2)”, “SH2(3)”, or “SH3(4)” (sample hold mode).
4
Set the rated capacity of the connected load cell in No.4 “L.C. Rated Capacity”.
The rated capacity of the load cell is shown on the certificate of the load cell.
5
Select the force unit from “N(0)”, “kgf(1)”, and “lbf(2)” in No.5 “Loadcell Unit”.
6
Set the rated output of the connected load cell in No.6 “L.C. Rated Output”. The
rated output of the load cell is shown on the certificate of the load cell.
7
Set No.8 “Force Measure Mode” (measurement mode of load cell) to “SH2(2)”
(sample hold 2 mode).
b. Setting of measurement schedule
1
Press MONI key to display the normal screen.
2
Press SCH key to select “SCH Axis”.
3
Select the setting object between “Axis1(0)” (first axis) and “Axis2(1)” (second
axis) to set the schedule number.
Welding start with
the set weld force !
Welding
Time
Force
Force
measurement
Weld start output
force point
Weld time
Содержание MU-100A