MU-100A
8. Function Setting
8-6
No
Item
Selections,
Setting range
Description
18
Sensor Motion
Detect
0.000 to
0.100
mm
Inputs the allowable vibration range of displacement
sensor.
Vibrates when the welding head moves down and it
stops by making contact with workpiece. Depending on
device, mechanical vibration occurs. To properly detect
the stop, allowable vibration range can be set. If
vibration stronger than the set allowable vibration range,
the sequence cannot move on. In such cases, change
the setting. When “0” is set, vibration is not checked.
Invalid when the LS Input Validity is set to Valid(0).
19
L.C. Motion Detect
At 20N: 0 to 2.00
At 50N: 0 to 5.00
At 200N: 0 to 20.0
At 500N: 0 to 50.0
At 2000N: 0 to 200
At 5000N: 0 to 500
At 10000N: 0 to 1000
Inputs the allowable vibration range of load cell.
Up to 10% of the load cell rated capacity can be set.
Vibrates when the welding head moves down and it
stops by making contact with workpiece. Depending on
device, mechanical vibration occurs. To properly detect
the stop, allowable vibration range can be set. If
vibration stronger than the set allowable vibration range,
the sequence cannot move on. In such cases, change
the setting. When “0” is set, vibration is not checked.
Invalid when the LS Input Validity is set to Valid(0).
20
Zero Point Setting
All(0)
Select(1)
Selects whether to set the origin of the displacement
sensor is set for all SCH simultaneously or each SCH.
All(0): all SCHs simultaneously
Select(1): each SCH
21
Head Error Time
0.00
to 9.99sec
Sets the time from the start signal input to the LS signal
input. When the force-detecting signal is not input even
after the time, an error occurs. When 0.00sec is set, the
error is not detected. Invalid when the LS Input Validity
is set to Invalid(1).
22
Finish Error Time
0.00
to 9.99sec
Sets the time from the WELD START signal output to
the FINISH signal input. When the FINISH signal is not
input even after the time, an error occurs. When 0.00sec
is set, the error is not detected.
23
Buzzer
On(0)
Off(1)
Sets whether to sound the buzzer at the occurrence of
error and NG.
On(0): Sound
Off(1): Do not sound
24
Tang Measure Point
Weld(0)
Hold(1)
When the measurement mode of the load cell is TANG,
selects the force measurement point, after Weld-Time or
after Hold-Time.
Weld(0): After Weld-Time
Hold(1): After Hold-Time
25
Brightness
0 to 10(
5
)
Adjusts the contrast.
26
Ready Output
Measurement ON(0)
Control ON(1)
Selects the output state of the ready output.
Measurement ON(0): Measurement available mode
The READY is not output at STOP input, occurrence
of NG/WARNING, measurement operation,
communication operation, WELD and HEAD
operation with panel switch, MANUAL measurement,
and schedule setting.
Control ON(1): Device operation mode
The READY is not output at WELD and HEAD
operation with panel switch, MANUAL measurement,
and schedule setting.
27
Disp Level Mode
HEIGHT1(0)
HEIGHT2(1)
Selects the type of measurement value displayed for
after-weld work thickness.
HEIGHT1(0): Makes the level setting with the travel
distance from the zero setting position
HEIGHT2(1): Makes the level setting setting the travel
distance after Before Work as 0.